7-24 Troubleshooting
Source:
HasCtrl
Type:
Information
Event ID: 1408
Description: Since removal of each device was not completed, the driver was not
able to bind the CPU/IO module. [Module[Module Number]]
[Module Number] “#0” or “#1”
IO module is not disconnected:
→
When you attempt to disconnect IO module while network adapter and/or SCSI
adapter and/or FC adapter is not in dual mode, the following message will be
recorded to the system event log and the IO module will not be separated. In this
case, check each adapter setting referring to “After starting up, FT Status LED do
not illuminate or illuminate amber” of this chapter.
Source:
HasCtrl
Type:
Warning
Event ID: 1505
Description: Device [Device name] is not duplexing.
[Device name] “LAN” or “SCSI” or “FC”
→
When you attempt to disconnect IO module when the HAS Fault Tolerance service
is not started, the following message will be recorded to the system event log and
the IO module will not be separated. In this case, refer to “After starting up, FT
Status LED do not illuminate or illuminate amber” of this chapter to start the HAS
Fault Tolerance service and retry disconnecting the I/O module.
Source:
HasCtrl
Type:
Warning
Event ID: 1506
Description: The doubleness information about an I/O device is not reported.
Summary of Contents for Express5800/320Fa-L
Page 2: ......
Page 19: ...Precautions for Use 1 3 Rack model Front Rear...
Page 45: ...General Description 2 13 Rack model with the front door open...
Page 48: ...2 16 General Description 27 HCS1 error LED See page 2 29 28 Heat warning LED See page 2 29...
Page 50: ...2 18 General Description Rear View Tower model Rack model...
Page 74: ...2 42 General Description This page is intentionally left blank...
Page 89: ...Windows Setup and Operation 3 15 7 Configure the mirror of the extended volume...
Page 107: ...Windows Setup and Operation 3 33 4 The confirmation dialog box appears Click Yes button...
Page 114: ...3 40 Windows Setup and Operation This page is intentionally left blank...
Page 141: ...System Configuration 4 27 Exit Move the cursor onto Exit to display the Exit menu...
Page 265: ...Installing and Using Utilities 5 65 Sample screen of Server Maintenance Utility...
Page 306: ...6 14 Maintenance This page is intentionally left blank...
Page 400: ...8 44 System Upgrade This page is intentionally left blank...
Page 404: ......
Page 405: ......