Appendix C
VME-MXI-2 Front Panel Configuration
© National Instruments Corporation
C-5
VME-MXI-2 User Manual
The characteristic impedance of the MXIbus signals is 120
Ω
.
Table C-2 lists additional characteristics of the MXIbus signals.
Table C-2. MXIbus Signal Characteristics
Signal Category
Voltage
Range
Max
Current
Frequency
Range
Each single-ended
signal
0 to 3.4 V
60 mA
DC to 10 Mhz
Each differential
signal (D17–D34)
0 to 5 V
80 mA
DC to 10 Mhz
Each 5 V (A35, A36)
5 V
1.75 A fused
DC
Each TERMPOWER
(B35, B36)
3.4 V
1.75 A fused
DC
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com