Chapter 5
System Configuration
VME-MXI-2 User Manual
5-28
© National Instruments Corporation
VME-MXI-2
VME-MXI-2
VME-MXI-2
VME-MXI-2
VXI-MXI-2
Multiframe
Resource
Manager
VME
bus
Mainframe
#1
MXIbus
Device
A
MXIbus
Device
B
VXI
bus
Mainframe
#2
VME
bus
Mainframe
#3
VME-MXI-2
VME
bus
Mainframe
#6
VME-MXI-2
VME
bus
Mainframe
#5
VME-MXI-2
VME
bus
Mainframe
#4
MXIbus #2
MXIbus #3
MXIbus #1
Level 1
Level 2
Figure 5-19. Example VMEbus/MXIbus System Diagram
Table 5-4. Example VMEbus/MXIbus System Required A16 Space
Device
Amount of A16
Space Required
VMEbus Mainframe #1
16 KB
MXIbus Device A
512 B
MXIbus Device B
0 B
VXIbus Mainframe #2
0 B
VMEbus Mainframe #3
4 KB
VMEbus Mainframe #4
2 KB
VMEbus Mainframe #5
1 KB
VMEbus Mainframe #6
2 KB