Chapter 1
Introduction
VME-MXI-2 User Manual
1-4
© National Instruments Corporation
•
Allows for optional or user-installable onboard DRAM up to
64 MB, which can be shared with the VMEbus and MXIbus
•
Conforms to the VMEbus specification
•
Conforms to VXI-6, the VXIbus Mainframe Extender Specification
•
Conforms to the MXI-2 specification
•
Supports automatic first slot detection
•
Supports automatic MXIbus System Controller detection
•
Supports automatic MXIbus termination
•
Has no restrictions on physical location of devices
The VME-MXI-2 generates all the support signals required by the
VMEbus:
•
VMEbus System Controller functions:
–
16 MHz system clock driver
–
Data transfer bus arbiter (PRI or RR ARBITER)
–
Interrupt acknowledge daisy-chain driver
•
VMEbus miscellaneous services:
–
VMEbus timeout (BTO)
–
Pushbutton system reset switch
•
VMEbus master capabilities:
–
Access to A16, A24, and A32 address space
–
D08(EO), D16, D32, and D64 accesses
–
Release-on-Request bus requester (programmable bus
request level)
–
Optional FAIR VMEbus requester
•
VMEbus slave capabilities:
–
A16, A24, and A32 address space
–
D08(EO), D16, D32, and D64 accesses
•
VMEbus interrupter
–
ROAK or RORA (programmable)
–
Responds to D16 or D32 IACK cycles
The VME-MXI-2 does not have support for the serial clock driver or
power monitor VMEbus modules.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com