Chapter 5
System Configuration
© National Instruments Corporation
5-15
VME-MXI-2 User Manual
MXIbus Link:
MXIbus #2
Device:
VMEbus Mainframe #6
Number of logical addresses required by device:
1
Range =
2
Round total number up to the next power of two:
1 (2
0
)
Size =
8-0 = 8
List other MXIbus links to this mainframe:
Number of logical addresses required by
additional MXIbus links:
+
0
Total number of logical addresses required by this device:
=
1
Range =
2
Round total number up to the next power of two:
*
1 (2
0
)
Size =
8-0 = 8
Device:
Number of logical addresses required by device:
Range =
Round total number up to the next power of two:
Size =
List other MXIbus links to this mainframe:
Number of logical addresses required by
additional MXIbus links:
+
Total number of logical addresses required by this device:
=
Range =
Round total number up to the next power of two:
*
Size =
Total Number of Logical Addresses Required:
1
(Add numbers after the “
*
”)
Range =
2
Round Total Number up to Next Power of Two:
1
(2
0
)
Size =
8-0 = 8
Figure 5-9. Worksheet 3 for MXIbus #2 of Example VMEbus/MXIbus System
MXIbus Link:
MXIbus #3
Device:
VMEbus Mainframe #4
Number of logical addresses required by device:
1
Range =
62
Round total number up to the next power of two:
1 (2
0
)
Size =
8-0 = 8
List other MXIbus links to this mainframe:
Number of logical addresses required by
additional MXIbus links:
+
0
Total number of logical addresses required by this device:
=
1
Range =
62
Round total number up to the next power of two:
*
1 (2
0
)
Size =
8-0 = 8
Device:
VMEbus Mainframe #5
Number of logical addresses required by device:
1
Range =
63
Round total number up to the next power of two:
1
(2
0
)
Size =
8-0 = 8
List other MXIbus links to this mainframe:
Number of logical addresses required by
additional MXIbus links:
+
0
Total number of logical addresses required by this device:
=
1
Range =
63
Round total number up to the next power of two:
*
1 (2
0
)
Size =
8-0 = 8
Total Number of Logical Addresses Required:
2
(Add numbers after the “
*
”)
Range =
62
–
63
Round Total Number up to Next Power of Two:
2
(2
1
)
Size =
8-1 = 7
Figure 5-10. Worksheet 4 for MXIbus #3 of Example VMEbus/MXIbus System
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com