
6
Installation
50
6.4.2 ODU Mounting Procedure
The ODU must be mounted using the following steps, ensuring that the cable entry is at the
bottom:
1. Attach the bracket strap to the pole using M8 x 70 mm bolts, M8 flat washers and M8
coil washers (Figure 19). Tighten to ensure the assembly grips but can be adjusted.
Figure 19 – ODU Bracket Strap
2. Offer the ODU (with pre-fitted mounting bracket) to the bracket strap and affix using
the captive M8 bolt. Tighten to ensure the assembly grips, but can be adjusted on the
pole (Figure 20 and Figure 21).
Figure 20 – ODU Mounting Bracket
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299