![Mitsubishi Electric QJ71GF11-T2 User Manual Download Page 425](http://html.mh-extra.com/html/mitsubishi-electric/qj71gf11-t2/qj71gf11-t2_user-manual_1811847425.webp)
423
CHAPTER 11 PROGRAMMING
11
11.
4
U
sing Link
Sp
ecial Relay
(S
B)
and Link
Sp
ecial Regist
er
(SW
)
(13)Canceling/restoring reserved station setting
Canceling/restoring reserved station setting is executed using the CC-Link IE Field Network diagnostics as well
as link special relays (SBs) and link special registers (SWs). (
(a) Canceling reserved station setting
1.
Specify the station number to cancel reserved station setting in Reserved station function disable/
temporary error invalid station setting (SW0010 to SW0017).
2.
Turn on Reserved station function disable request (SB0012).
3.
Reserved station function disable request accept status (SB005C) is turned on.
4.
When reserved station setting is cancelled, Reserved station function disable completion status
(SB005D) turns on.
5.
Reserved station function disable status (SB0180) is turned on and the station number of the
station in reserved station function disable status is stored in Reserved station cancel setting
status (SW0180 to SW0187).
6.
When the reserved station setting is cancelled with error, an error code will be stored in Result of
reserved station function disable (SW0056).
7.
Turn off Reserved station function disable request (SB0012).
(b) Restoring reserved station setting
1.
Specify the station number to restore reserved station setting in Reserved station function
disable/temporary error invalid station setting (SW0010 to SW0017),
2.
Turn on Reserved station specification enable request (SB0013).
3.
Reserved station specification enable request accept status (SB005E) is turned on.
4.
When cancellation of the reserved station specification is completed, Reserved station
specification enabled status (SB005F) is turned on.
5.
Use Reserved station function disable status (SW0180 to SW0187) to check whether the station
returned to the reserved station. Reserved station function disable status (SB0180) is turned off.
6.
When the reserved station setting is restored with error, an error code will be stored in Result of
reserved station function enable (SW0057).
7.
Turn off Reserved station specification enable request (SB0013).
Number
Description
Number
Description
SB0012
Reserved station function disable request
SW0010 to
SW0017
Reserved station function disable/temporary error
invalid station setting
SB005C
Reserved station function disable request accept
status
SW0056
Result of reserved station function disable
SB005D
Reserved station function disable completion status
SB0180
Reserved station function disable status
SW0180 to
SW0187
Reserved station cancel setting status
Number
Description
Number
Description
SB0013
Reserved station specification enable request
SW0010 to
SW0017
Reserved station function disable/temporary error
invalid station setting
SB005E
Reserved station specification enable request accept
status
SW0057
Result of reserved station function enable
SB005F
Reserved station specification enabled status
SB0180
Reserved station function disable status
SW0180 to
SW0187
Reserved station function disable status