![Mitsubishi Electric QJ71GF11-T2 User Manual Download Page 371](http://html.mh-extra.com/html/mitsubishi-electric/qj71gf11-t2/qj71gf11-t2_user-manual_1811847371.webp)
369
CHAPTER 10 DEDICATED INSTRUCTIONS
10
10.
17 G
P
.C
C
PAS
ET
(Set
ting Param
e
te
rs)
10.
17.
2
In
st
ru
ct
ion det
ai
ls
(2) Function
(a) CCPASET instruction overview
Set parameters for the master/local module.
(b) Target stations that can be specified
Only the master and local modules of the own station can be accessed.
(c) Checking the execution status of the CCPASET instruction
The execution status (completion or error) of the CCPASET instruction can be checked using the following
devices specified in the setting data.
• Completion device (D)
This device turns on in the END process of the scan where the CCPASET instruction is completed and
turns off in the next END process.
• Completion status indication device ((D)+1)
If the CCPASET instruction fails, this device turns on in the END process of the scan where the CCPASET
instruction is completed and turns off in the next END process.
Parameter
setting
CPU module
Master/local
module
[Own station]
CCPASET