418
(9) Checking parameter status
The reflection status and setting contents of parameters can be checked using link special relays (SBs) and link
special registers (SWs).
(a) Checking the parameter status (other stations)
1.
When a station on the network has a parameter error, Parameter error status (each station)
(SB0170) is turned on.
When the submaster function is used, the parameter status of the station number 0 can be checked using
Parameter error status (station No.0) (SB017F).
2.
The station number where the parameter error occurs is stored in Parameter error status (each
station) (SW0170 to SW0177).
3.
Details on the parameters on each station can be checked using link special relays (SBs) and link
special registers (SWs) on each station.
Number
Description
Number
Description
SB0170
Parameter error status (each station)
SW0170 to
SW0177
Parameter error status (each station)
SB017F
Parameter error status (station No.0)