![Mitsubishi Electric QJ71GF11-T2 User Manual Download Page 296](http://html.mh-extra.com/html/mitsubishi-electric/qj71gf11-t2/qj71gf11-t2_user-manual_1811847296.webp)
294
10.9
JP/GP.RECV (Receiving Data from the Programmable
Controller on Another Station)
This instruction reads the data received from the programmable controller on another station. (For the main routine
program)
*1
Local devices and file registers set for each program cannot be used.
(1) Setting data
Setting
data*
1
Available devices
Internal device
(System, user)
File
register
R, ZR
Link direct device
J
\
Intelligent function
module device
U
\G
Index register
Zn
Constant
Others
Bit
Word
Bit
Word
K, H
$
(S1)
(D1)
(D2)
Setting data
Description
Set by
Data type
Jn
Own station's network No. (1 to 239, 254)
254: Network specified in Valid Module During Other Station Access
User
16-bit binary
Un
Start I/O number of the master/local module of the own station
(00 to FE
H
: Upper two digits of the I/O number expressed in three
digits)
(S1)
Start device of the own station where control data is stored
Device name
(D1)
Start device of the own station where received data is stored
(A continuous area for the received data length is required.)
System
(D2)
The device of the own station that turns on for one scan upon
completion of the instruction.
If the instruction fails, (D2)+1 also turns on.
Bit
JP.RECV
Start contact
GP.RECV
Start contact
JP.RECV
Jn
GP.RECV
Un
(S1)
(D1)
(D2)
(S1)
(D1)
(D2)