287
CHAPTER 10 DEDICATED INSTRUCTIONS
10
10.
8
J
P
/G
P
.SEN
D (S
ending Da
ta
to
the
Pro
g
ramm
able Cont
roller
on A
n
ot
her
S
tat
io
n
)
*1
If Completion status ((S1)+1) is "Channel in use (dedicated instruction) (error codes: D25A
H
and D25B
H
)", data is not
stored.
●
When the SEND instruction is executed to the same channel on a target station
Execute the SEND instruction after the target station reads data of the specified channel.
If the SEND instruction is executed to the same channel on the target station before the data is read from the specified
channel of the target station, an error occurs.
●
When multiple network modules are connected on the target station
Specify the network No. and station No. of the network module that accepts requests from the own station.
Specifying the station No. 1 in network No. 1 (station No. 5 in network No. 2 cannot be specified.)
(S1)+17
Error-detected
station number*
1
The station number of the station in which an error was detected is
stored.
(Data is stored when "1: Data at the time of abnormal end is set in
the area starting from (S1)+11." is set in the abnormal end type in
(S1)+0.) The stored data is not cleared even if the dedicated
instruction is normally completed.
Master station: 125 (7D
H
)
Local station, intelligent device station, submaster station: 1 to 120
System
Device
Item
Setting data
Setting range
Set by
RECV
Target station
Error
Own station
Master/local
module
Master/local
module
CPU module
CPU module
Channel 2
Channel 1
Channel 2
Channel 1
SEND
SEND
Network No.1
Ex.
Station
No.0
Station
No.1
Station
No.2
Station
No.3
Station
No.5
Station
No.1
Network No.1
Network No.2
(Own station)
(Target station)
Specify station No.1 as the target station.
Station No.5 cannot be specified.