Appendix 2 Remote Registers
Module operation area (RWw0)
■
Initial processing completion flag (RWw0.b8)
Turning on this flag completes the initial processing and turns on Remote READY (RWr0.b11).
For the timing of turning the flag on and off, refer to the following.
Page 140 Initial processing request flag (RWr0.b8)
■
Operation condition setting request flag (RWw0.b9)
Write the setting data and then turn on Operation condition setting request flag (RWw0.b9). After the operation condition is
changed, Operation condition setting completion flag (RWr0.b9) turns on.
For the timing of turning the flag on and off, refer to the following.
Page 142 Operation condition setting completion flag (RWr0.b9)
• Turning on Operation condition setting request flag (RWw0.b9) stores 0000H in Warning code (RWr2) and
turns off Warning status flag (RWr0.b12).
• When a major error or a moderate error occurs and the error cause is eliminated, turning on Operation
condition setting request flag (RWw0.b9) stores 0000H in Error code (RWr1) and turns off Error status flag
(RWr0.b10).
■
Error clear request flag (RWw0.b10)
Use this flag to clear Error status flag (RWr0.b10) and Error code (RWr1).
• When a moderate error occurs
When Error clear request flag (RWw0.b10) is turned on after the cause of the error is eliminated, the error status is cleared
and Error status flag (RWr0.b10) turns off.
If Error clear request flag (RWw0.b10) is turned off before Error status flag (RWr0.b10) turns off, Error status flag (RWr0.b10)
does not turn off.
• When a major error occurs
Error status flag (RWr0.10) does not turn off even if Error clear request flag (RWw0.b10) is turned on and off.
Channel n output process data (from RWw4)
The output process data depends on the IO-Link device used.
For details, refer to the manual of the IO-Link device used.
Because the process data size varies depending on the connected IO-Link device, specify the value not less
than the total process data size of the IO-Link device used. (
Summary of Contents for CC-Link IE Field NZ2GF12A-60IOLH8
Page 1: ...CC Link IE Field Network Waterproof Remote IO Link Module User s Manual NZ2GF12A 60IOLH8 ...
Page 2: ......
Page 30: ...28 3 PROCEDURES BEFORE OPERATION MEMO ...
Page 100: ...98 8 MODULE FUNCTION BLOCKS MEMO ...
Page 109: ...9 PROGRAMMING 9 2 Program Example of Setting Parameters Using a Dedicated Instruction 107 9 ...
Page 116: ...114 9 PROGRAMMING 9 3 Example of Program to Communicate with an IO Link Device ...
Page 118: ...116 10 MAINTENANCE AND INSPECTION MEMO ...
Page 155: ...APPX Appendix 7 Additional or Changed Functions 153 A MEMO ...
Page 157: ...I 155 MEMO ...
Page 161: ......