APPX
Appendix 1 Remote I/O Signals
131
A
Details of remote input signals
Channel n (CQ/Q) external input signal 0 to F (RX0 to RXF)
The input ON/OFF status is applied from the external device connected to each channel. (n = 1 to 8)
Devices available for this signal differ depending on the mode.
: Available,
: Not available
Device
number
Signal name
Description
Mode
IO-Link
mode
SIO
mode
(digital
input)
SIO mode
(digital
output)
RX0
Channel 1 (CQ) external input signal 0
The input ON/OFF status is applied from the external device
connected to channel 1 to the CQ terminal.
RX1
Channel 1 (Q) external input signal 1
The input ON/OFF status is applied from the external device
connected to channel 1 to the Q terminal.
RX2
Channel 2 (CQ) external input signal 2
The input ON/OFF status is applied from the external device
connected to channel 2 to the CQ terminal.
RX3
Channel 2 (Q) external input signal 3
The input ON/OFF status is applied from the external device
connected to channel 2 to the Q terminal.
RX4
Channel 3 (CQ) external input signal 4
The input ON/OFF status is applied from the external device
connected to channel 3 to the CQ terminal.
RX5
Channel 3 (Q) external input signal 5
The input ON/OFF status is applied from the external device
connected to channel 3 to the Q terminal.
RX6
Channel 4 (CQ) external input signal 6
The input ON/OFF status is applied from the external device
connected to channel 4 to the CQ terminal.
RX7
Channel 4 (Q) external input signal 7
The input ON/OFF status is applied from the external device
connected to channel 4 to the Q terminal.
RX8
Channel 5 (CQ) external input signal 8
The input ON/OFF status is applied from the external device
connected to channel 5 to the CQ terminal.
RX9
Channel 5 (Q) external input signal 9
The input ON/OFF status is applied from the external device
connected to channel 5 to the Q terminal.
RXA
Channel 6 (CQ) external input signal A
The input ON/OFF status is applied from the external device
connected to channel 6 to the CQ terminal.
RXB
Channel 6 (Q) external input signal B
The input ON/OFF status is applied from the external device
connected to channel 6 to the Q terminal.
RXC
Channel 7 (CQ) external input signal C
The input ON/OFF status is applied from the external device
connected to channel 7 to the CQ terminal.
RXD
Channel 7 (Q) external input signal D
The input ON/OFF status is applied from the external device
connected to channel 7 to the Q terminal.
RXE
Channel 8 (CQ) external input signal E
The input ON/OFF status is applied from the external device
connected to channel 8 to the CQ terminal.
RXF
Channel 8 (Q) external input signal F
The input ON/OFF status is applied from the external device
connected to channel 8 to the Q terminal.
Summary of Contents for CC-Link IE Field NZ2GF12A-60IOLH8
Page 1: ...CC Link IE Field Network Waterproof Remote IO Link Module User s Manual NZ2GF12A 60IOLH8 ...
Page 2: ......
Page 30: ...28 3 PROCEDURES BEFORE OPERATION MEMO ...
Page 100: ...98 8 MODULE FUNCTION BLOCKS MEMO ...
Page 109: ...9 PROGRAMMING 9 2 Program Example of Setting Parameters Using a Dedicated Instruction 107 9 ...
Page 116: ...114 9 PROGRAMMING 9 3 Example of Program to Communicate with an IO Link Device ...
Page 118: ...116 10 MAINTENANCE AND INSPECTION MEMO ...
Page 155: ...APPX Appendix 7 Additional or Changed Functions 153 A MEMO ...
Page 157: ...I 155 MEMO ...
Page 161: ......