(G) Control parameters
617
5
GROUP
G
5.16.12
Increased magnetic excitation deceleration
Setting of increased magnetic excitation rate (Pr.660, Pr.661)
• To enable the increased magnetic excitation deceleration, set
Pr.660 Increased magnetic excitation deceleration
operation selection
= "1".
• Set the amount of excitation increase in
Pr.661 Magnetic excitation increase rate
. Increased magnetic excitation
deceleration will be disabled when
Pr.661
= "0".
• When the DC bus voltage exceeds the increased magnetic excitation deceleration operation level during the deceleration,
excitation is increased in accordance with the setting value in
Pr.661
.
• The increased magnetic excitation deceleration will continue even if the DC bus voltage goes under the increased magnetic
excitation deceleration operation level (850 V) during increased magnetic excitation deceleration.
• When the stall prevention (overvoltage) occurs during the increased magnetic excitation deceleration operation, increase
the deceleration time or raise the setting value of
Pr.661
. When the stall prevention (overcurrent) occurs, increase the
deceleration time or lower the setting value of
Pr.661
.
• Increased magnetic excitation deceleration is enabled with V/F control, Advanced magnetic flux vector control, Real
sensorless vector control (speed control), and vector control (speed control).
NOTE
• The increased magnetic excitation deceleration will be disabled in the following conditions:
During PM sensorless vector control, power failure stop, orientation control, energy saving operation, Optimum excitation
control, and stop-on-contact control.
Increase the loss in the motor by increasing the magnetic flux at the time of deceleration. Deceleration time can be
reduced by suppressing the stall prevention (overvoltage) (oL).
It will make possible to reduce the deceleration time without a brake resistor. (Usage can be reduced if a brake resistor
is used)
Pr.
Name
Initial
value
Setting
range
Description
660
G130
Increased magnetic
excitation deceleration
operation selection
0
0
Without increased magnetic excitation deceleration
1
With increased magnetic excitation deceleration
661
G131
Magnetic excitation
increase rate
9999
0 to 40%
Set the increase of excitation.
9999
Magnetic excitation increase rate 10% under V/F control and
Advanced magnetic flux vector control
Magnetic excitation increase rate 0% under Real sensorless
vector control and vector control
662
G132
Increased magnetic
excitation current level
100%
0 to 300%
The increased magnetic excitation rate is automatically
lowered when the output current exceeds the setting value at
the time of increased magnetic excitation deceleration.
V/F
V/F
V/F
Magnetic flux
Magnetic flux
Magnetic flux Sensorless
Sensorless
Sensorless Vector
Vector
Vector
Summary of Contents for 800 Series
Page 11: ...MEMO 10 ...
Page 17: ...MEMO 16 ...
Page 95: ...MEMO 94 ...
Page 671: ...MEMO 670 ...
Page 681: ...MEMO 680 ...