(A) Application parameters
480
Continuous multi-point orientation (V/F control, Advanced magnetic flux
vector control)
• Orientation command and orientation with STF/STR ON. (Orientation in servo-in status)
• The position data is read at the rising edge of DY. (For the details, refer to the Instruction Manual of FR-A8AX).
• When the position signal is within the creep switchover position, the speed starts up to the creep speed not to the
orientation speed.
• When the position signal is outside the creep switchover position, the speed starts up to the orientation speed.
• The DC injection brake operates if the position signal is within the DC injection brake start position.
• 16-bit data with the FR-A8AX is valid only when the DY signal is ON.
NOTE
• Couple the encoder with the motor shaft or with the shaft that stops the main shaft at the specified position. Couple it with the
speed ratio of 1:1 and without any mechanical looseness.
• The DC injection brake operates at orientation stop. Release the DC injection brake as soon as possible (within several
seconds), as continuous operation of the DC injection brake will cause the motor to overheat, leading to burnout.
• Because the servo lock function is not available after orientation stop, provide a holding mechanism, such as a mechanical
brake or knock pin, when secure holding of the main shaft is required.
• To ensure correct positioning, the encoder must be set in the proper rotation direction, and the A and B phases must be
connected correctly.
• If the pulse signal from the encoder stops due to encoder signal loss, etc. during orientation, the Orientation fault (ORM)
signal may be output.
• When performing orientation control, enable the DC injection brake. (Refer to
.) When the DC injection brake is
disabled, orientation operation cannot be completed.
• When orientation control is performed, the DC injection brake operates regardless of the External DC injection brake
operation start (X13) signal even when
Pr.11 DC injection brake operation time
= "8888" (DC injection brake external
selection).
• To terminate orientation, the start signal (STF or STR) must be first switched OFF, and then the X22 signal must be switched
OFF. As soon as this X22 signal is switched OFF, orientation control ends. (Depending on the
Pr.358 Servo torque
selection
setting, the orientation status continues if the X22 signal remains ON even if the DC injection brake is released by
turning OFF the start signal. Because of this, the orientation status on the monitor does not show "0".
• When the retry function of
Pr.358 Servo torque selection
is selected, the retry operation is performed three times including
the first orientation.
• When performing orientation control, properly set
Pr.350 Stop position command selection
and
Pr.360 16-bit data
selection (external position command selection)
. If the values are set incorrect, proper orientation control will not be
performed.
• When orientation control is performed, PID control is disabled.
DY
Position signal
Servo-in
ON
ON
Position command latch
50ms or more is necessary
Servo-in
ON
ON
Position command latch
Main spindle speed (encoder)
Pr.351
Pr.352
Start signal
Orientation command
Orientation complete signal
Orientation speed (orientation switchover speed)
Creep speed (orientation deceleration ratio)
Summary of Contents for 800 Series
Page 11: ...MEMO 10 ...
Page 17: ...MEMO 16 ...
Page 95: ...MEMO 94 ...
Page 671: ...MEMO 670 ...
Page 681: ...MEMO 680 ...