(E) Environment setting parameters
259
5
GROUP
E
5.7.13
Extended parameter display and user group
function
The read value is always "9999".
Display of simple mode parameters and extended parameters (Pr.160)
• When
Pr.160
= "9999", only the simple mode parameters can be displayed on the operation panel and the parameter unit.
(For the simple mode parameters, refer to the parameter list
.)
• With the initial value (
Pr.160
= "0"), simple mode parameters and extended parameters can be displayed.
NOTE
• When a plug-in option in installed on the inverter, the option parameters can also be read.
• Every parameter can be read regardless of the
Pr.160
setting when reading parameters via a communication option.
• When reading the parameters using the RS-485 terminals, all parameters can be read regardless of the
Pr.160
setting by
setting
Pr.550 NET mode operation command source selection
and
Pr.551 PU mode operation command source
selection
.
User group function (Pr.160, Pr.172 to Pr.174)
• The user group function is a function for displaying only the parameters required for a setting.
• A maximum of 16 parameters from any of the parameters can be registered in a user group. When
Pr.160
="1", reading/
writing is enabled only for the parameters registered in user groups. (Parameters not registered in user groups can no
longer be read.)
• To register a parameter in a user group, set the parameter number in
Pr.173
.
• To clear a parameter from a user group, set the parameter number in
Pr.174
. To batch clear all the registered parameters,
set
Pr.172
="9999".
This function restricts the parameters that are read by the operation panel and parameter unit.
Pr.
Name
Initial value
Setting range
Description
160
E440
User group read selection
0
9999
Only simple mode parameters can be
displayed.
0
Simple mode and extended parameters
can be displayed.
1
Only parameters registered in user groups
can be displayed.
172
E441
User group registered
display/batch clear
0
(0 to 16)
Displays the number of groups that are
registered as user groups. (Read-only)
9999
Batch clear of user group registrations
173
E442
User group registration
9999
0 to 1999, 9999
Sets the parameter number to register for
the user group.
174
E443
User group clear
9999
0 to 1999, 9999
Sets the parameter number to clear from
the user group.
Pr.551
Pr.550
Pr.160 enabled/disabled
1 (RS-485)
-
Enabled
2 (PU)
3 (USB)
9999 (Automatic determination)
(Initial value)
0 (
Communication option
)
Enabled
1 (RS-485)
Disabled (All can be read)
9999 (Automatic determination)
(Initial value)
With communication option: Enabled
Without communication option: Disabled
(All can be read)