(M) Monitor display and monitor output signal
356
NOTE
• When indication with negative numbers is enabled for the output via terminal AM (analog voltage output), the output is within
the range of -10 to +10 VDC. Connect a meter suitable for the output.
• Parameter unit displays only unsigned numbers.
Monitor filter (Pr.1106 to Pr.1108)
• The response level (filter time constant) of the following monitor indicators can be adjusted.
???????
Parameters referred to
Pr.30 Regenerative function selection, Pr.70 special regenerative brake duty
Pr.37 motor speed display, Pr.144 Speed setting switchover
Pr.55 Frequency monitoring reference, Pr.56 Current monitoring reference, Pr.866 Torque monitoring reference
Pr.
Monitor number
Monitor indicator name
1106
7
Motor torque
17
Load meter
32
Torque command
33
Torque current command
1107
6
Running speed
1108
18
Motor excitation current