282
10 Ethernet
10.2 Applying the Communication Setting to a Device Supporting iQSS
10.2
Applying the Communication Setting to a Device
Supporting iQSS
The communication setting set in the "Ethernet Configuration" window can be applied to a device supporting iQSS.
Perform this function after adding, deleting or changing the setting of a device supporting iQSS.
Operating procedure
The target device supporting iQSS must be restarted after performing a reflection of communication setting to
Ethernet devices.
For the operating status of a device supporting iQSS, refer to the manuals of each device supporting iQSS.
Considerations when applying the communication setting to a device supporting iQSS
■
Specifying a port number
• Do not specify '45237' for a port number in other devices on the same Ethernet network.
It may cause an error in other devices on the same Ethernet network.
• Do not specify the number from '61440' to '65534' for the own station port number.
The connection establishment instruction (SP.SOCOPEN) of the socket communication function may be completed
abnormally.
• Do not specify the IP address of a device supporting iQSS for the IP address of an external device, nor the number from
'61440' to '65534' for the destination port number.
The connection establishment instruction (SP.SOCOPEN) of the socket communication function may be completed
abnormally when performing a sensor/device monitor or a sensor parameter read/write.
■
Changing the communication setting in the "Ethernet Configuration" window
When the communication setting written to a CPU module in the "Ethernet Configuration" window does not match with that of
a device supporting iQSS, the communication cannot be established normally.
When the communication setting is changed in the "Ethernet Configuration" window, perform a reflection of communication
setting to Ethernet devices in order to match the communication setting between a CPU module and a device supporting
iQSS.
1.
Enter the communication setting.
2.
Select a target device supporting iQSS in the "Ethernet
Configuration" window, then right-click and select [Online]
[Communication Setting Reflection of Ethernet Device] from
the shortcut menu.
The communication setting is applied to the target device
supporting iQSS.
When using a device supporting iQSS that does
not support the host name, even if the reflection
function of the communication setting is performed
with a host name entered, it will not be applied to
the device.
After performing the automatic detection function
of connected devices, the "Host Name" field will be
blank.
For the applicability of the host name of a device
supporting iQSS, refer to the manuals of each
device supporting iQSS.
Summary of Contents for 13JV28
Page 1: ...iQ Sensor Solution Reference Manual ...
Page 2: ......
Page 166: ...164 6 Ethernet 6 5 Backing up Restoring Data of Devices Supporting iQSS MEMO ...
Page 185: ...7 AnyWireASLINK 7 4 Backing up Restoring Data of Devices Supporting iQSS 183 7 Sample program ...
Page 195: ...7 AnyWireASLINK 7 4 Backing up Restoring Data of Devices Supporting iQSS 193 7 Sample program ...
Page 228: ...226 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...
Page 238: ...236 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...
Page 244: ...242 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...
Page 309: ...10 Ethernet 10 5 Backing up Restoring Data of Devices Supporting iQSS 307 10 Sample program ...
Page 371: ...APPX Appendix 8 Backup File Capacity 369 A MEMO ...
Page 373: ...I 371 MEMO ...
Page 377: ......