7 AnyWireASLINK
7.4 Backing up/Restoring Data of Devices Supporting iQSS
177
7
■
Setting the backup setting
1.
Setting a target module type
Set a target module with the lower 8 bits of SD1362 (iQ Sensor Solution data backup/restoration target module, execution unit
setting).
2.
Setting an execution unit
Set a unit to specify the range of data to be backed up at once.
Specify the execution unit to the upper 8 bits of SD1362.
3.
Setting a number for a data backup folder name
Set a folder number to SD1363 (iQ Sensor Solution backup/restoration folder number setting).
*1 When the specified folder number exists, the operation to be performed depends on the specification of the execution unit as follows:
4.
Setting a target device
• Setting a module
When '1H' (module unit) is set for the execution unit, set a start I/O number to SD1364 (iQ Sensor Solution data backup/
restoration target setting (target module)).
In a multiple CPU system, only the AnyWireASLINK master module controlled by a host CPU can be backed up. Data backup
cannot be performed for non-controlled modules.
• Setting an ID number
When '2H' (ID unit) is set for the execution unit, set an ID number to SD1365 (iQ Sensor Solution data backup/restoration
target setting (target device 1)).
Target module type
Description
1H: AnyWireASLINK
Set this to specify a device supporting iQSS which is connected to the AnyWireASLINK master module.
Execution unit
Description
1H: Module unit
Set this to specify all devices supporting iQSS which are connected to the AnyWireASLINK master module with
the specified start I/O number.
2H: ID unit
Set this to specify the device supporting iQSS with the specified ID number among the devices which are
connected to the AnyWireASLINK master module with the specified start I/O number.
Target folder
Description
FFFFH: Automatic specification (default)
Among the numbers (0 to 99) that are not used for backup folder names, the smallest number is used for a new
backup folder name.
An error occurs when unused number is no longer available due to such cases as the number of folders reached
the upper limit.
FFFEH: Automatic specification (folder
deletion supported)
Among the numbers (0 to 99) that are not used for backup folder names, the smallest number is used for a new
backup folder name.
The oldest backup folder (date_number) is deleted and the number of the deleted folder is used for a new backup
folder name when unused number is no longer available due to such cases as the number of folders reached the
upper limit.
0 to 99: Target folder specification
Specify a number (0 to 99) of the backup folder name.
When another folder with the same number exists, the target data is overwritten in execution unit without
changing the folder name.
Execution unit
Operation
1H: Module unit
When the backup data with the same target module exists, the backup folder (start I/O number_ID) is deleted
before performing data backup.
2H: ID unit
When the backup data with the same target module and the same target ID exists, the backup folder (start I/O
number_ID) is deleted before performing data backup.
Target device (Module)
Description
0 to FFH: Start I/O number
Set the start I/O number (the value obtained by dividing the start I/O number by 16) of the AnyWireASLINK
master module which is connected to a target device supporting iQSS.
Target device (ID number)
Description
0 to 9999: ID number
Set the ID number of a target device supporting iQSS.
Summary of Contents for 13JV28
Page 1: ...iQ Sensor Solution Reference Manual ...
Page 2: ......
Page 166: ...164 6 Ethernet 6 5 Backing up Restoring Data of Devices Supporting iQSS MEMO ...
Page 185: ...7 AnyWireASLINK 7 4 Backing up Restoring Data of Devices Supporting iQSS 183 7 Sample program ...
Page 195: ...7 AnyWireASLINK 7 4 Backing up Restoring Data of Devices Supporting iQSS 193 7 Sample program ...
Page 228: ...226 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...
Page 238: ...236 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...