5 CC-Link IE Field Network
5.1 Detecting Devices Supporting iQSS Automatically
101
5
■
Detection methods of a system configuration
The system configuration of CC-Link IE Field Network can also be detected by either of the following operations.
• Click the [Detect Now] button in the "CC IE Field Configuration" window.
• Select [Online]
[Detect Now] in MELSOFT Navigator.
For the operation methods of MELSOFT Navigator, refer to the following manual.
(
Let's start iQ Works Version 2)
Detected devices to be displayed in the CC IE Field Configuration window
Modules detected after performing an automatic detection of connected devices are displayed differently depending on
whether a profile has been registered.
■
A profile has been registered
• The module model names are displayed in "Model Name".
• "Local Station", "Intelligent Device Station", "Remote Device Station", or "Remote I/O Station" is displayed in the column of
"Station Type".
Note that a sub-master station of a CC-Link IE Field Network master/local module or GOT1000/2000 series is displayed as
follows:
• For a sub-master station of a CC-Link IE Field Network master/local module, the module model name is displayed in the
column of "Model Name" and "Local Station" is displayed in the column of "Station Type".
• For GOT1000/2000 series, "Gen. Intelligent Device Station" is displayed in the column of "Model Name" and "Intelligent
Device Station" is displayed in the column of "Station Type".
■
A profile has not been registered
• "General Local Station", "General Sub-Master Station", "Gen. Intelligent Device Station", "General Remote Device Station",
or "General Remote I/O Station" is displayed in the column of "Model Name".
• "Local Station", "Sub-Master Station", "Intelligent Device Station", "Remote Device Station", or "Remote I/O Station" is
displayed in the column of "Station Type".
When using the master station with a serial number whose first five digits are '17021' or lower, or using the
versions of devices supporting iQSS that do not support an automatic detection of connected devices, the
information will not be displayed properly in the column of "Model Name" and "Station Type" even though a
profile has been registered.
Summary of Contents for 13JV28
Page 1: ...iQ Sensor Solution Reference Manual ...
Page 2: ......
Page 166: ...164 6 Ethernet 6 5 Backing up Restoring Data of Devices Supporting iQSS MEMO ...
Page 185: ...7 AnyWireASLINK 7 4 Backing up Restoring Data of Devices Supporting iQSS 183 7 Sample program ...
Page 195: ...7 AnyWireASLINK 7 4 Backing up Restoring Data of Devices Supporting iQSS 193 7 Sample program ...
Page 228: ...226 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...
Page 238: ...236 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...
Page 244: ...242 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...
Page 309: ...10 Ethernet 10 5 Backing up Restoring Data of Devices Supporting iQSS 307 10 Sample program ...
Page 371: ...APPX Appendix 8 Backup File Capacity 369 A MEMO ...
Page 373: ...I 371 MEMO ...
Page 377: ......