9 CC-Link IE Field Network
9.1 Detecting Devices Supporting iQSS Automatically
Detected devices to be displayed in the CC IE Field Configuration window
Modules detected after performing an automatic detection of connected devices are displayed differently depending on
whether a profile has been registered.
■
A profile has been registered
• The module model names are displayed in "Model Name".
• "Local Station", "Intelligent Device Station", "Remote Device Station", or "Remote I/O Station" is displayed in the column of
"Station Type".
Note that a sub-master station of a CC-Link IE Field Network-equipped master/local module or GOT1000/2000 series is
displayed as follows:
• For a sub-master station of a CC-Link IE Field Network-equipped master/local module, the module model name is
displayed in the column of "Model Name" and "Local Station" is displayed in the column of "Station Type".
• For GOT1000/2000 series, "Gen. Intelligent Device Station" is displayed in the column of "Model Name" and "Intelligent
Device Station" is displayed in the column of "Station Type".
■
A profile has not been registered
• The module model names, "General Local Station", "Gen. Intelligent Device Station", "General Remote Device Station", or
"General Remote I/O Station" is displayed in the column of "Model Name".
• "Local Station", "Sub-Master Station", "Intelligent Device Station", "Remote Device Station", or "Remote I/O Station" is
displayed in the column of "Station Type".
When using the master station whose firmware version is 02 or earlier, or using the versions of modules that
do not support an automatic detection of connected devices, the information will not be displayed properly in
the column of "Model Name" and "Station Type", even though a profile has been registered.
The "CC IE Field Configuration" window appears.
4.
Click the [Detect Now] button.
The actual system configuration is displayed in the "CC IE Field
Configuration" window.
5.
Select [Close with Reflecting the Setting] in the "CC IE Field
Configuration" window.
Information such as parameters displayed in the "CC IE Field
Configuration" window is applied to the network parameter.
Summary of Contents for 13JV28
Page 1: ...iQ Sensor Solution Reference Manual ...
Page 2: ......
Page 166: ...164 6 Ethernet 6 5 Backing up Restoring Data of Devices Supporting iQSS MEMO ...
Page 185: ...7 AnyWireASLINK 7 4 Backing up Restoring Data of Devices Supporting iQSS 183 7 Sample program ...
Page 195: ...7 AnyWireASLINK 7 4 Backing up Restoring Data of Devices Supporting iQSS 193 7 Sample program ...
Page 228: ...226 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...
Page 238: ...236 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...
Page 244: ...242 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...
Page 309: ...10 Ethernet 10 5 Backing up Restoring Data of Devices Supporting iQSS 307 10 Sample program ...
Page 371: ...APPX Appendix 8 Backup File Capacity 369 A MEMO ...
Page 373: ...I 371 MEMO ...
Page 377: ......