344
APPX
Appendix 4 Considerations for Using Device Supporting iQSS
Panasonic Industrial Devices SUNX Co., Ltd.
Type/model name
Function
Consideration
■
Communication unit for CC-Link
• SC-GU3-01
• Sensor parameter read/write
• Sensor/device monitor
Communication unit for CC-Link is required to be interconnected with
respective sensor amplifiers supporting optical communication, and to which
an end unit (SC-GU3-EU) is attached at the end.
Neither the sensor parameter read/write function nor the sensor/device
monitor function can be performed on the station without an end unit.
Data backup/restoration
Communication unit for CC-Link is required to be interconnected with
respective sensor amplifiers supporting optical communication, to which an
end unit (SC-GU3-EU) is attached at the end.
The station to which no end unit is attached, the data may not be backed up
properly.
When one communication unit for CC-Link is connected to the CC-Link
master/local module, the error code 4805H is stored to SD1452 during the
data backup process.
When two or more communication unit for CC-Link are connected to CC-Link
master/local module, and if a station without an end unit is included, data
backup is performed only on the station with an end unit, not on the station
without an end unit.
Note that error code is not stored.
■
Analog input unit
• SC-T1JA
• SC-A01
• SC-A02
Sensor/device monitor
When performing the Sensor/Device Monitor function, connecting an analog
voltage output signal of other device to an analog voltage input terminal is
required.
If no signal is connected, '0' is obtained as a current value.
■
Digital fiber sensor
• FX-301
• FX-305
• FX-501
• FX-502
Sensor/device monitor
When performing the sensor/device monitor function, connecting a fiber
head to a digital fiber sensor is required.
Data can be obtained even if a fiber head is not connected, but a detected
value differs from a value detected when a fiber head is connected.
Data backup/restoration
When data backup/restoration failed, an error code is stored to SD1453.
Check the error code and take corrective actions. (
List, or
User's manual for data backup/restoration target modules)
■
Digital laser sensor
• LS-403
Sensor/device monitor
When performing the sensor/device monitor function, connecting a laser
sensor head to a digital laser sensor is required.
Data can be obtained even if a laser sensor head is not connected, but a
detected value differs from a value detected when a laser sensor head is
connected.
Data backup/restoration
When data backup/restoration failed, an error code is stored to SD1453.
Check the error code and take corrective actions. (
List, or
User's manual for data backup/restoration target modules)
■
Head-separated dual display
digital pressure sensor
• DPS-401
• DPS-402
Sensor/device monitor
When performing the sensor/device monitor function, connecting a pressure
sensor head to a head-separated dual display digital pressure sensor is
required.
When a pressure sensor head is not connected, '0' is acquired for a detected
value and 'Er42' is displayed on a sensor amplifier.
Data backup/restoration
When data backup/restoration failed, an error code is stored to SD1453.
Check the error code and take corrective actions. (
List, or
User's manual for data backup/restoration target modules)
Summary of Contents for 13JV28
Page 1: ...iQ Sensor Solution Reference Manual ...
Page 2: ......
Page 166: ...164 6 Ethernet 6 5 Backing up Restoring Data of Devices Supporting iQSS MEMO ...
Page 185: ...7 AnyWireASLINK 7 4 Backing up Restoring Data of Devices Supporting iQSS 183 7 Sample program ...
Page 195: ...7 AnyWireASLINK 7 4 Backing up Restoring Data of Devices Supporting iQSS 193 7 Sample program ...
Page 228: ...226 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...
Page 238: ...236 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...
Page 244: ...242 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...
Page 309: ...10 Ethernet 10 5 Backing up Restoring Data of Devices Supporting iQSS 307 10 Sample program ...
Page 371: ...APPX Appendix 8 Backup File Capacity 369 A MEMO ...
Page 373: ...I 371 MEMO ...
Page 377: ......