5 CC-Link IE Field Network
5.5 Backing up/Restoring Data of Devices Supporting iQSS
129
5
■
Devices used in the program
Set the devices used in the program by refresh parameters in advance.
*1 Devices when the remote input (RX) is set from 'D2000' to 'D2001' by the refresh parameter setting.
For details on special relays (SM) and special registers (SD) to be used and their setting ranges, refer to the
following section.
Page 355 Special Relay (SM)/Special Register (SD) List
Device
Description
Value
M0
Initialization trigger
M1000
Restoration execution trigger
M1100
Restoration right-to-use request trigger
M1200
Restoration right-to-use confirmation trigger
M1300
Restoration setting/start trigger
M2000
Restoration execution cancellation trigger
M3000
Restoration execution normal completion display
M3500
Restoration execution abnormal completion display
M3550
Restoration right-to-use acquisition failure
D1000
Right-to-use number storage area
D2000.0
Remote READY
D2000.1
DP/DN short error
D2000.3
Transmission cable voltage drop error
D2000.4
DP/DN disconnection error
D2001.0
Slave module alarm signal
D2001.1
Parameter access completion flag
D2001.2
Parameter access error
D2001.4
Automatic address detection flag
D5000
Restoration number of normally completed devices
D5001
Restoration number of devices completed with an error
D5002
Restoration error cause in a module
D5003
Restoration error cause in a device
SM1435
Restoration execution enabled
SM1439
Restoration request
SM1442
Restoration cancellation request
SD1435
Restoration use request
1080H
SD1436
Restoration right-to-use acquisition status
SD1437
Restoration target module/execution unit setting
Lower 8 bits: 4H
Upper 8 bits: 3H
SD1438
Restoration folder number setting
24
SD1439
Restoration target setting (target module)
3H
SD1440
Restoration target setting (target device 1)
1
SD1441
Restoration target setting (target device 2)
517
SD1444
Operation setting when a data restoration error occurs
1H
SD1446
Restoration execution status
SD1448
Restoration number of normally completed devices
SD1449
Restoration number of devices completed with an error
SD1452
Restoration error cause in a module
SD1453
Restoration error cause in a device
SW0B0.0
Station No.1 data link status
X30
Module error
X31
Host station data link status
X3F
Module READY
Summary of Contents for 13JV28
Page 1: ...iQ Sensor Solution Reference Manual ...
Page 2: ......
Page 166: ...164 6 Ethernet 6 5 Backing up Restoring Data of Devices Supporting iQSS MEMO ...
Page 185: ...7 AnyWireASLINK 7 4 Backing up Restoring Data of Devices Supporting iQSS 183 7 Sample program ...
Page 195: ...7 AnyWireASLINK 7 4 Backing up Restoring Data of Devices Supporting iQSS 193 7 Sample program ...
Page 228: ...226 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...
Page 238: ...236 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...
Page 244: ...242 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...
Page 309: ...10 Ethernet 10 5 Backing up Restoring Data of Devices Supporting iQSS 307 10 Sample program ...
Page 371: ...APPX Appendix 8 Backup File Capacity 369 A MEMO ...
Page 373: ...I 371 MEMO ...
Page 377: ......