10 Ethernet
10.5 Backing up/Restoring Data of Devices Supporting iQSS
301
10
■
Setting the restoration setting
1.
Setting a target module type
Set a target module with the lower 8 bits of SD1362 (iQ Sensor Solution data backup/restoration target module, execution unit
setting).
2.
Setting an execution unit
Set a unit to specify the range of data to be restored at once.
Specify the execution unit to the upper 8 bits of SD1362.
3.
Selecting a folder for data restoration
Set a folder number to SD1363 (iQ Sensor Solution backup/restoration folder number setting).
4.
Setting a target device
• Setting a module
When '1H' (module unit) is set for the execution unit, set a module to SD1364 (iQ Sensor Solution data backup/restoration
target setting (target module)).
• Setting IP addresses
When '2H' (IP address unit) is set for the execution unit, set target devices (IP address) to SD1365 (iQ Sensor Solution data
backup/restoration target setting (target device 1)) and SD1366 (iQ Sensor Solution data backup/restoration target setting
(target device 2)).
*1 IP addresses within the range from 0.0.0.1 to 223.255.255.254
5.
Setting the operation setting when a data restoration error occurs
Set the operation to be performed when the data restoration fails on some devices while being processed to multiple devices
supporting iQSS to the lower 8 bits of SD1367 (iQ Sensor Solution data backup/restoration operation setting).
Target module type
Description
3H: Ethernet
Set this to specify a device supporting iQSS which is connected to Ethernet.
Execution unit
Description
1H: Module unit
Set this to collect the information of the device supporting iQSS connected to an Ethernet and to perform data
restoration.
Devices supporting iQSS which communicate with a restoration target module are restored.
2H: IP address unit
Set this to specify the device supporting iQSS with the specified IP address among the devices supporting iQSS
which are connected to Ethernet.
Target folder
Description
0 to 99: Target folder specification
Specify a number (0 to 99) of the backup folder name to be restored.
Target device (Module)
Description
03FFH: Built-in Ethernet
Set this to specify a device supporting iQSS which is connected to a built-in Ethernet.
Number
Target device (IP address)
Description
SD1365
0 to 65536 (FFFFH): IP address (lower 16 bits)
Set the IP address of a target device supporting iQSS.
SD1366
0 to 57343 (DFFFH): IP address (upper 16 bits)
Operation on error
Description
0H: Continue
Set this to continue a data restoration even if it fails on some devices.
1H: Stop
Set this to stop a data restoration if it fails on some devices.
Summary of Contents for 13JV28
Page 1: ...iQ Sensor Solution Reference Manual ...
Page 2: ......
Page 166: ...164 6 Ethernet 6 5 Backing up Restoring Data of Devices Supporting iQSS MEMO ...
Page 185: ...7 AnyWireASLINK 7 4 Backing up Restoring Data of Devices Supporting iQSS 183 7 Sample program ...
Page 195: ...7 AnyWireASLINK 7 4 Backing up Restoring Data of Devices Supporting iQSS 193 7 Sample program ...
Page 228: ...226 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...
Page 238: ...236 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...
Page 244: ...242 8 CC Link 8 4 Backing up Restoring Data of Devices Supporting iQSS Sample program ...
Page 309: ...10 Ethernet 10 5 Backing up Restoring Data of Devices Supporting iQSS 307 10 Sample program ...
Page 371: ...APPX Appendix 8 Backup File Capacity 369 A MEMO ...
Page 373: ...I 371 MEMO ...
Page 377: ......