D-31
2) Removal of the CCD Unit
1. Open the Electronic Document Hander.
2. Remove the Control Panel.
3. Remove the Original Glass.
4. Slide the Scanner all the way to the left.
7. Unplug three connectors from PWB-IB.
8. Remove one screw, three ground wire mounting screws, and the CCD Unit.
1155D051AD
5. Loosen three screws indicated by the arrow.
6. Remove six screws and the board cover.
1) When removing the CCD Unit, remove only the three screws specified. (That is, remove the CCD
Unit as one unit.)
2) After the CCD Unit has been reinstalled, perform Scale (CD), Zoom (CD), Position (CD) and S-
ADF Mode (CD). In addition to these adjustments, perform Address Adjust and Orig. Size Adjust
also, if the CCD Unit has been replaced with a new one.
NOTES
1155D039AC
Summary of Contents for Di620
Page 1: ...Di 620 GENERAL MECHANICAL ELECTRICAL ...
Page 5: ...1151SBG000CA GENERAL ...
Page 19: ...1155SAM000CA MACHANICAL ELECTRICAL ...
Page 140: ...M 121 Multi Copy Cycle Immediately After Warm up in Early Morning normal CPM 62 1155M082CA ...
Page 153: ...Di620 SWITCHES ON PWBs TECH REP SETTINGS 1155SBS000AA ...
Page 211: ...Di620 TROUBLESHOOTING ...
Page 238: ...M E M O ...
Page 304: ...Di620 DIS REASSEMBLY ADJUSTMENT ...
Page 427: ......
Page 428: ......
Page 429: ......
Page 430: ......
Page 433: ......
Page 434: ......
Page 435: ......
Page 436: ......
Page 437: ......
Page 438: ......
Page 439: ......
Page 440: ......
Page 441: ......
Page 442: ......
Page 443: ......
Page 444: ......
Page 445: ......
Page 446: ......
Page 447: ......
Page 448: ......
Page 449: ......
Page 450: ......
Page 451: ......
Page 452: ......
Page 453: ......
Page 454: ......
Page 455: ......
Page 456: ......
Page 457: ......
Page 458: ......
Page 459: ......
Page 460: ......
Page 461: ......
Page 462: ......
Page 463: ......
Page 464: ......
Page 465: ......