T-43
◆
C004B
◆
C004C
Step
Check Item
Result
Action
1
Check M32 for operation.
Does the voltage across PJ10A-9B on
PWB-A and GND change from DC0V to
DC24V when the malfunction is reset?
NO
Change PWB-A.
2
Does the voltage across PJ10A-11B on
PWB-A and GND change from DC5V to
DC0V when the malfunction is reset?
YES
Change PWB-A.
NO
Check gears for overload and, if they are
okay, change M17.
Step
Check Item
Result
Action
1
Check M12 for operation.
Does the voltage across PJ10A-7B on
PWB-A and GND change from about
DC16V to DC24V when the Start key is
pressed?
NO
Change PWB-A.
2
Does the voltage across PJ10A-5B on
PWB-A and GND change from DC5V to
DC0V when the malfunction is reset?
YES
Change PWB-A.
NO
Check gears for overload and, if they are
okay, change M12.
Summary of Contents for Di620
Page 1: ...Di 620 GENERAL MECHANICAL ELECTRICAL ...
Page 5: ...1151SBG000CA GENERAL ...
Page 19: ...1155SAM000CA MACHANICAL ELECTRICAL ...
Page 140: ...M 121 Multi Copy Cycle Immediately After Warm up in Early Morning normal CPM 62 1155M082CA ...
Page 153: ...Di620 SWITCHES ON PWBs TECH REP SETTINGS 1155SBS000AA ...
Page 211: ...Di620 TROUBLESHOOTING ...
Page 238: ...M E M O ...
Page 304: ...Di620 DIS REASSEMBLY ADJUSTMENT ...
Page 427: ......
Page 428: ......
Page 429: ......
Page 430: ......
Page 433: ......
Page 434: ......
Page 435: ......
Page 436: ......
Page 437: ......
Page 438: ......
Page 439: ......
Page 440: ......
Page 441: ......
Page 442: ......
Page 443: ......
Page 444: ......
Page 445: ......
Page 446: ......
Page 447: ......
Page 448: ......
Page 449: ......
Page 450: ......
Page 451: ......
Page 452: ......
Page 453: ......
Page 454: ......
Page 455: ......
Page 456: ......
Page 457: ......
Page 458: ......
Page 459: ......
Page 460: ......
Page 461: ......
Page 462: ......
Page 463: ......
Page 464: ......
Page 465: ......