T-13
<Copier Take-Up Misfeed Clearing Procedure>
Symptom
Step
Check Item
Result
Action
•
Paper is not
taken up at all.
•
Paper is at a
stop before the
Vertical Trans-
port Sensor.
1
Does the paper being used meet
product specifications?
NO
Instruct the user to use the
paper that meets product
specifications.
2
Is the paper curled, wavy, or damp?
YES
Change the paper. Instruct
the user on the storage of
paper.
3
Are the Edge Guide and Trailing Edge
Stop (of the drawer) positioned to the
exact sizes of the paper used?
NO
Slide the guides to the exact
size of the paper.
4
Are the Paper Take-Up Roll and Paper
Separator Roll deformed, worn, or
dirty with paper dust?
YES
Clean or change the defec-
tive roll.
5
Is the Paper Take-Up Guide Plate dirty
or deformed?
YES
Clean or change the guide
plate.
6
When the 1st Drawer is use
Check CL3 for operation.
Does the voltage across PJ15F-2B on
PWB-F and GND change from DC24V
to DC0V when the Start key is
pressed?
YES
Change CL3.
NO
Change PWB-F or PWB-A.
7
When the 2nd Drawer is use
Check CL4 for operation.
Does the voltage across PJ14F-2B on
PWB-F and GND change from DC24V
to DC0V when the Start key is
pressed?
YES
Change CL4.
NO
Change PWB-F or PWB-A.
8
When the 3rd Drawer is use
Check CL5 for operation.
Does the voltage across PJ13F-2B on
PWB-F and GND change from DC24V
to DC0V when the Start key is
pressed?
YES
Change CL5.
NO
Change PWB-F or PWB-A.
Paper is at a
stop in the verti-
cal transport
section.
1
Are the Vertical Transport Rollers
deformed, worn, or dirty with paper
dust?
YES
Clean or change the Vertical
Transport Rollers.
2
Is the Paper Take-Up or Vertical
Transport Guide Plate deformed or
dirty?
YES
Clean or change the defec-
tive guide plate.
3
Does M22 turn when the Start key is
pressed?
NO
Check for overload. Then,
check step 5 and onward.
4
Is each of the voltages across PJ17F-
1 on PWB-F and GND and that across
PJ17F-2 and GND DC38V?
YES
Change M22.
NO
Change PWB-A or PWB-F.
5
Is each Paper Take-Up Sensor (PC32,
33, 34) fully operational? Make the
input port check using “I/O Check.”
NO
Check the actuator of the
defective sensor for opera-
tion and, if it is okay, change
the sensor.
6
Is each Vertical Transport Sensor
(PC36, 37, 38) fully operational?
Make the input port check using “I/O
Check.”
YES
Change PWB-F or PWB-A.
NO
Check the actuator of the
defective sensor for opera-
tion and, if it is okay, change
the sensor.
Summary of Contents for Di620
Page 1: ...Di 620 GENERAL MECHANICAL ELECTRICAL ...
Page 5: ...1151SBG000CA GENERAL ...
Page 19: ...1155SAM000CA MACHANICAL ELECTRICAL ...
Page 140: ...M 121 Multi Copy Cycle Immediately After Warm up in Early Morning normal CPM 62 1155M082CA ...
Page 153: ...Di620 SWITCHES ON PWBs TECH REP SETTINGS 1155SBS000AA ...
Page 211: ...Di620 TROUBLESHOOTING ...
Page 238: ...M E M O ...
Page 304: ...Di620 DIS REASSEMBLY ADJUSTMENT ...
Page 427: ......
Page 428: ......
Page 429: ......
Page 430: ......
Page 433: ......
Page 434: ......
Page 435: ......
Page 436: ......
Page 437: ......
Page 438: ......
Page 439: ......
Page 440: ......
Page 441: ......
Page 442: ......
Page 443: ......
Page 444: ......
Page 445: ......
Page 446: ......
Page 447: ......
Page 448: ......
Page 449: ......
Page 450: ......
Page 451: ......
Page 452: ......
Page 453: ......
Page 454: ......
Page 455: ......
Page 456: ......
Page 457: ......
Page 458: ......
Page 459: ......
Page 460: ......
Page 461: ......
Page 462: ......
Page 463: ......
Page 464: ......
Page 465: ......