T-30
Code
Description
Detection Timing
C0990 3rd Drawer lift-up failure
•
3rd Drawer Paper Lift-Up Sensor PC42 is not blocked
([L]) even when 3rd Drawer Elevator Motor Pulse Sen-
sor PC29 has detected 400 HIGH-going and LOW-
going edges after 3rd Drawer Elevator Motor M28 has
started turning forward (for upward motion); or, PC42
is not blocked ([L]) even after the lapse of 10 sec. after
M28 has started turning forward.
•
PC42 is not blocked ([L]) even after the lapse of 3 sec.
after 3rd Drawer Paper Empty Sensor (PC50) has
been blocked ([L]) while M28 is turning forward (for
upward motion).
•
Either 3rd Drawer Lower Position Sensor PC20 or 3rd
Drawer Overrun Detecting Sensor PC21 is not
unblocked ([H]) even after 60 edges are counted after
M28 has started turning forward (for upward motion).
•
PC20 is not blocked ([L]) even after 400 edges are
counted after M28 has started turning backward (for
downward motion); or, PC21 is not blocked ([L]) even
after the lapse of 10 sec. after M28 has started turning
backward.
•
PC21 is not blocked ([L]) even after the lapse of 3 sec.
after PC20 has been blocked ([L]) while M28 is turning
backward (for downward motion).
•
PC42 is not unblocked ([H]) even after 40 edges are
counted after M28 has started turning backward (for
downward motion).
•
PC21 is not blocked ([L]) when PC20 is blocked ([L])
while M28 is turning forward (for upward motion) or
backward (for downward motion).
C0994 3rd Drawer Elevator Motor M28's
failure to turn
3rd Drawer Elevator Motor Pulse Sensor PC29 detects
no HIGH-going or LOW-going edges even after the
lapse of 500 msec. after M28 has started turning for-
ward (for upward motion) or backward (for downward
motion).
C0996 3rd Drawer lock release failure
The 3rd Drawer is not pushed out even after the lapse of
10 sec. after three repeated cycles of keeping 3rd
Drawer Lock Solenoid SL6 energized for 500 msec., an
attempt of pushing the 3rd Drawer out.
C0997 3rd Drawer Shift Gate motion fail-
ure
•
The input to 3rd Drawer Shift Gate Position Sensor
PC52 remains LOW even after the lapse of 2 sec. after
3rd Drawer Shift Gate Motor M30 has been energized
with a LOW input to PC52.
•
The input to PC52 remains HIGH even after the lapse
of 2 sec. after M30 has been energized with a HIGH
input to PC52.
Summary of Contents for Di620
Page 1: ...Di 620 GENERAL MECHANICAL ELECTRICAL ...
Page 5: ...1151SBG000CA GENERAL ...
Page 19: ...1155SAM000CA MACHANICAL ELECTRICAL ...
Page 140: ...M 121 Multi Copy Cycle Immediately After Warm up in Early Morning normal CPM 62 1155M082CA ...
Page 153: ...Di620 SWITCHES ON PWBs TECH REP SETTINGS 1155SBS000AA ...
Page 211: ...Di620 TROUBLESHOOTING ...
Page 238: ...M E M O ...
Page 304: ...Di620 DIS REASSEMBLY ADJUSTMENT ...
Page 427: ......
Page 428: ......
Page 429: ......
Page 430: ......
Page 433: ......
Page 434: ......
Page 435: ......
Page 436: ......
Page 437: ......
Page 438: ......
Page 439: ......
Page 440: ......
Page 441: ......
Page 442: ......
Page 443: ......
Page 444: ......
Page 445: ......
Page 446: ......
Page 447: ......
Page 448: ......
Page 449: ......
Page 450: ......
Page 451: ......
Page 452: ......
Page 453: ......
Page 454: ......
Page 455: ......
Page 456: ......
Page 457: ......
Page 458: ......
Page 459: ......
Page 460: ......
Page 461: ......
Page 462: ......
Page 463: ......
Page 464: ......
Page 465: ......