S-42
Tech. Rep. Mode I.R. & EDH Check
Touch Panel Display
Setting
I.R. & EDH Check
Function (EDH)
Performs the following functions.
Pos./Zoom (FD)
Automatically adjusts the zoom ratio and the scanning position in the FD
(sub-scanning) direction when the EDH is used and shows the results.
Note 1: Run this function after making sure that the result of the Skew
Check is within 1.0%.
Note 2: The Touch Panel shows “OK” if the adjustment value falls within
the specified range, and “NG” if it falls outside the range. It gives
the message of “Unable” if the adjustment sequence is abnormally
terminated.
<Procedure>
1. Load the chart in the EDH.
2. Press the Start key to start the measurement cycle.
3. If the measurement result is okay, touch [Save] (which highlights the
key) to save the measurement.
Note: The copier automatically stops as soon as it completes the measure-
ment cycle. The Stop key may, however, be pressed to halt the
sequence.
Position (CD)
Automatically adjusts the scanning position in the CD (main scanning)
direction when the EDH is used and shows the results.
Note 1: Run this function after making sure that the result of the Skew
Check is within 1.0%.
Note 2: The Touch Panel shows “OK” if the adjustment value falls within
the specified range, and “NG” if it falls outside the range. It gives
the message of “Unable” if the adjustment sequence is abnormally
terminated.
<Procedure>
1. Load the chart in the EDH.
2. Press the Start key to start the measurement cycle.
3. If the measurement result is okay, touch [Save] (which highlights the
key) to save the measurement.
Note: The copier automatically stops as soon as it completes the measure-
ment cycle. The Stop key may, however, be pressed to halt the
sequence.
S-ADF Mode (CD)
Adjusts the scanning position (CD) for a single feed scan.
Note: The Touch Panel shows “OK” if the adjustment value falls within the
specified range, and “NG” if it falls outside the range. It gives the
message of “Unable” if the adjustment sequence is abnormally ter-
minated.
<Procedure>
1. Insert the chart into the Single Feed Tray, which starts the measure-
ment cycle. (There is no need of pressing the Start key.)
2. If the measurement result is okay, touch [Save] (which highlights the
key) to save the measurement.
Note: The copier automatically stops as soon as it completes the measure-
ment cycle. The Stop key may, however, be pressed to halt the
sequence.
▼
Summary of Contents for Di620
Page 1: ...Di 620 GENERAL MECHANICAL ELECTRICAL ...
Page 5: ...1151SBG000CA GENERAL ...
Page 19: ...1155SAM000CA MACHANICAL ELECTRICAL ...
Page 140: ...M 121 Multi Copy Cycle Immediately After Warm up in Early Morning normal CPM 62 1155M082CA ...
Page 153: ...Di620 SWITCHES ON PWBs TECH REP SETTINGS 1155SBS000AA ...
Page 211: ...Di620 TROUBLESHOOTING ...
Page 238: ...M E M O ...
Page 304: ...Di620 DIS REASSEMBLY ADJUSTMENT ...
Page 427: ......
Page 428: ......
Page 429: ......
Page 430: ......
Page 433: ......
Page 434: ......
Page 435: ......
Page 436: ......
Page 437: ......
Page 438: ......
Page 439: ......
Page 440: ......
Page 441: ......
Page 442: ......
Page 443: ......
Page 444: ......
Page 445: ......
Page 446: ......
Page 447: ......
Page 448: ......
Page 449: ......
Page 450: ......
Page 451: ......
Page 452: ......
Page 453: ......
Page 454: ......
Page 455: ......
Page 456: ......
Page 457: ......
Page 458: ......
Page 459: ......
Page 460: ......
Page 461: ......
Page 462: ......
Page 463: ......
Page 464: ......
Page 465: ......