69
11-3-4. Operating condition of the comparator hysteresis
The comparator hysteresis is a function for the chattering prevention of the output relay.
The comparator hysteresis operating conditions is selected by setting function F-24.
The operating conditions of the comparator hysteresis can be selected from [On delay] and [Off
delay].
[On delay] is selected as a default.
11-3-5. Data width of the comparator hysteresis
The data width of the comparator hysteresis is set by setting function F-25.
Setting range : 00 ~ 99 Unit : 1D 00
:
OFF
Default has set [00].
ex. About the S2, the operation of the judge display and the comparator output when the
comparator hysteresis is set is shown
(1) [On delay]
(2) [Off delay]
Hysteresis data width
Time
S2 set value
ON
OFF
Display
S2 judge display
Comparator
S2 set value
Hysteresis data width
Time
ON
OFF
Display
S2 judge display
Comparator