37
5-2. Contents table of C-function
Item
C-Function No.
Setting value
Contents
Display position of decimal
point.
CF-01
*0
No decimal point
1 1234.5
2 123.45
3 12.345
Condition of over display
CF-03
0
Bigger than |The maximum
capacity
+
9D|
1
Exceeding to the maximum
capacity
±
110 %
*2
Smaller than -20D and larger than
maximum capacity
+
9D
Unit
(Unit setting at RS
corresponding output)
CF-05
*0 No
unit
1 G
2 Kg
3 T
4 Lb
Operating condition of
zero set
CF-10
*0
Operation when it is steady
1
Operation by unconditional
Effective range of zero set
CF-11
*0
±
2 % of the maximum capacity
1
±
10 % of the maximum capacity
Target of zero tracking
CF-12
0
Gross value and net value
*1 Gross
value
Data width of zero tracking
CF-13
00 ~ 99
Unit : 0.5 D
00 : Zero tracking OFF
*01
Time width of zero
tracking
CF-14
0 ~ 9
Unit : 0.5 s
0 : Zero tracking OFF
*2
Operation of power on
zero
CF-15
*0 Effective
1 Invalidity
Operating condition of tare
weight cancellation
CF-16
*0
Operation when it is steady
1
Operation by unconditional
Setting the storing
memory of the setting data
CF-17
00 ~ 11
0: store in RAM
1: store in EEPROM
10: zero set data
10: tare data
*00
Method of setting gravity
acceleration
compensation
CF-25
*0
Set the district number
1
Set a numeric value for gravity
acceleration.
District number of using
place
CF-26
(Possible to set at CF25
=
0)
01 ~ 16
Unit District
*10
District number of
calibration place
CF-27
(Possible to set at CF25
=
0)
01 ~ 16
Unit :District
*10
Gravity acceleration value
setting of using place
CF-28
(Possible to set at CF25
=
1)
9.000 ~ 9.999
*9.797
Unit : m/s2
* : Set as default
Summary of Contents for CSD-401