49
Items Function
No.
Setting value
Contents
Comparator comparison
operation
F-20
0 OFF
1 All
data
2
All data only weight is stable
3 Exceed
+5D
data
*4
5D data only weight is stable
5
Beyond the range of data -5D to +5D
6
Beyond the range of data -5D to +5D only
weight is stable.
7 Throw
mode
8 Discharge
mode
Target of comparator comparison
operation
(Target when F-20 is set by 1 to
6.)
F-21
00000 ~
22222
*00000
0 : Display interlock
1 : Gross value
2 : Net value
10
0
digit : S1 operating target
10
1
digit : S2 operating target
10
2
digit : S3 operating target
10
3
digit : S4 operating target
10
4
digit : S5 operating target
Direction of comparator
comparison operation
(Direction when F-20 is set by 1
to 6.)
F-22
00000 ~
22222
*00000
0 : OFF
1 : OVER
2 : LESS
10
0
digit : S1 operating
10
1
digit : S2 operating
10
2
digit : S3 operating
10
3
digit : S4 operating
10
4
digit : S5 operating
Operation of comparator S1
F-23
0
On at (Gross weight)
≧
(measuring weight)
1
On at S2, S3 output
2
On at S2, S4 output
3
On at S2, S5 output
4
On at S3, S4 output
5
On at S3, S5 output
6
On at S3, S5 output
7
On at S4, S5 output
Comparator hysteresis operating
conditions
F-24
*0 ON
delay
1 OFF
delay
Width of comparator hysteresis
data
F-25
00 ~ 99
*00
Unit : 1D
00 : Hysteresis OFF
BCD output operation mode
F-30
*0
Stream (outputs synchronizing with the
display frequency.)
1
Synchronizes with the print.
(Synchronize with
key, external
control input or the automatic print.)
* : has been set as default.