68
Example: movement of comparator
Function F-20 [5] (Only out of the -5D ~ +5D data and condition is stable)
Target of movement of comparator Function F-21 [1] (Gross)
S3: 5 000
S2: 1 000
S1: ON at (S2 setting value)
<
(display value)
<
(S3 setting value)
Display Small
Display Large
S3
S2
S1
ON
S2 set value
ON
OFF
ON
S3 set value
OFF
OFF