E-4
Apnea ventilation
ON
ATRC (only in non-NIV
mode)
OFF
Tube diameter (only in
non-NIV mode)
8.0mm
Compensation proportion
(only in non-NIV mode)
80%
Compensation of expiration
(only in non-NIV mode)
ON
P-SIMV
O2% 40%
fSIMV
Adult: 5 bpm; pediatric: 20 bpm
Pinsp 15
cmH2O
PEEP 3
cmH2O
△
Psupp 0
cmH2O
Tinsp
Adult: 1.7s; pediatric: 0.7s
Tslope 0.2s
F-Trig
Adult: 2.0 L/min; pediatric: 1.0 L/min
Exp% Auto
fapnea
Adult: 12 bpm; pediatric: 29 bpm
Apnea ventilation
ON
ATRC (only in non-NIV
mode)
OFF
Tube diameter (only in
non-NIV mode)
8.0mm
Compensation proportion
(only in non-NIV mode)
80%
Compensation of expiration
(only in non-NIV mode)
ON
PRVC
TV
Adult: 7 kg/mL x IBW and 100 ml, whichever is greater; pediatric:
7 kg/mL x IBW (round down) (when TV/f source is patient
weight)
Adult: 500 ml; pediatric: 50 ml (when TV/f source is patient type)
f
Adult: 12 bpm; pediatric: 29 bpm
O2% 40%
Plimit 40
cmH2O
PEEP 3
cmH2O
Tinsp
Adult: 1.7s; pediatric: 0.7s
Summary of Contents for SynoVent E5
Page 1: ...SynoVent E5 Ventilator Operator s Manual...
Page 2: ......
Page 24: ...2 2 2 2 Equipment Appearance 2 2 1 Front View 4 1 2 3 5 6 7 8 9 10 11 12...
Page 46: ...3 18 FOR YOUR NOTES...
Page 60: ...4 14 FOR YOUR NOTES...
Page 68: ...5 8 FOR YOUR NOTES...
Page 92: ...6 24 FOR YOUR NOTES...
Page 118: ...9 12 FOR YOUR NOTES...
Page 154: ...A 8 FOR YOUR NOTES...
Page 169: ...B 15 Temperature C Life 1192 exp 2 0 0239 Temperature Life of 20 C Figure...
Page 170: ...B 16 FOR YOUR NOTES...
Page 184: ...D 8 FOR YOUR NOTES...
Page 195: ......
Page 196: ...P N 046 000991 00 10 0...