background image

Chapter 10 myDataweb server

Chapter 10 myDataweb server

Note: All of the screenshots show version 38.1 of the myDataweb server using the standard colour scheme. Newer
versions may include minor changes to the appearance of the server.

10.1 Overview

Overview of the myDataweb server

1 Tabs to switch between the individual server

areas

5 Logout the active user

2 Freely selectable logo

6 Call up the help menu

3 User group to which the user that is currently

logged in is assigned

7 Switches to the "Data exports" area to

configure the data export. This tab is only
visible if at least the licence for one export
variant is available.

4 Opens the screen to input the global settings

for the server

8 Opens the input screen to upload a XML file.

This tab is only visible if the licence for the
XML import is available.

10.1.1 Explanation of the symbols

Adds a new entry to the current list (reports, sites, users, etc.).

Deletes the adjacent element (reports, sites, users, etc.) from the list.

Calls up the input screen to edit the adjacent element (reports, sites, users, etc.).

Rev. 01

57

Summary of Contents for myDatalogNANOamr

Page 1: ...Firmware version 03v005 l Modem version 03v005 l Server version 38 1 l Hardware version 1 1 User manual 300436 Microtronics Engineering GmbH www microtronics at Hauptstrasse 7 3244 Ruprechtshofen Austria Tel 43 2756 77180 23 Fax 43 2756 77180 33 support microtronics at ...

Page 2: ......

Page 3: ...ing GSM GPRS modems 14 4 4 2 1 Safety and precautionary measures for the GSM GPRS modem installation 14 4 4 2 2 Safety measures for installing the antenna 15 4 5 Overview 16 4 6 Intended use 16 4 7 General product information 17 4 8 Device labelling 17 4 9 Installation of replacement and wear parts 18 4 10 Storage of the product 18 4 11 Obligation of the operator 18 Chapter 5 Functioning principle...

Page 4: ...2 Connection of the GSM antenna 35 7 4 3 Optimum antenna positioning for assembly in a shaft 36 7 4 3 1 Influences on the signal quality 36 7 4 3 2 Possibilities for improving the signal quality 37 7 4 3 3 Procedure for determining the optimum position of the antenna 37 7 4 4 Technical details about the meter inputs 37 7 4 5 Technical details about the device operating time 38 Chapter 8 Initial St...

Page 5: ...9 2 1 4 2 Calculation 51 9 2 1 4 3 Alarm 52 9 2 1 5 Internal channels 52 9 2 1 5 1 Basis 52 9 2 1 6 Alarm settings 52 9 2 1 7 Basic setting 53 9 2 1 8 FTP export settings 53 9 2 2 Device configuration 54 9 2 2 1 Comments 54 9 2 2 2 Measurement instrument 54 9 2 2 3 Device specific settings 55 9 2 2 4 GPRS 56 Chapter 10 myDataweb server 57 10 1 Overview 57 10 1 1 Explanation of the symbols 57 10 2 ...

Page 6: ...ser level 1 73 11 4 2 2 User level 2 74 Chapter 12 XML interface 75 12 1 General 75 12 2 Structure of the database 75 12 2 1 Generally applicable table identifiers 76 12 2 1 1 mydatalognanoamrid 76 12 2 1 2 geraetid 83 12 2 1 3 bookingline read only 85 12 2 1 4 kundeid 85 12 2 2 Device specific table identifier 87 12 2 2 1 mydatalognanoamr_data 87 12 2 2 2 mydatalognanoamr_channel 88 12 2 2 3 myda...

Page 7: ...ample 97 12 3 1 2 Data record compression 99 12 3 1 3 Updating data fields 100 12 3 1 3 1 Example 100 12 3 2 Format of the XML result 101 12 3 2 1 Example 102 12 4 XML import 102 12 4 1 Transferring data to the myDataweb server 102 12 4 2 Configuration of a HTTP POST command 103 12 4 3 Structure of the XML file 104 12 4 3 1 Changing existing data 104 12 4 3 2 Importing data 104 Chapter 13 Maintena...

Page 8: ...e myDataweb server 120 15 3 2 Evaluating the device log using myDatanetDeviceConfig 120 Chapter 16 Spare parts and accessories 121 16 1 Assembly sets 121 16 2 Antennas 121 16 3 Battery packs 121 16 4 Other accessories 121 Chapter 17 Document history 123 Chapter 18 Contact information 125 8 Rev 01 ...

Page 9: ...Chapter 2 Declaration of conformity Chapter 2 Declaration of conformity Rev 01 9 ...

Page 10: ......

Page 11: ...puts 4 x meters Minimum pulse length 1ms Additional information is provided in Technical details about the meter inputs on page 37 Data memory Internal flash memory for up to 17 050 measurement cycles Data type s64 64 Bit signed Data transmission By means of GSM GPRS quad band modem to the respective myDataweb server SIM The myDatalogNANOamr is equipped with an integrated SIM chip Monthly data vol...

Page 12: ......

Page 13: ...iginal manual German must be referenced or the manufacturer contacted for clarification 4 2 Copyright The copying and distribution of this document as well as the utilisation and communication of its contents to others without express authorisation is prohibited Contraventions are liable to compensation All rights reserved 4 3 General descriptive names The use of general descriptive names trade na...

Page 14: ... text 4 4 2 Safety and preventative measures for handling GSM GPRS modems Observe the following safety and preventative measures during all phases of installation operation maintenance or repair of a GSM GPRS modem The manufacturer shall not be held liable if the customer disregards these preventative measures CAUTION The GSM GPRS modem connection may not be used in hazardous environments No guara...

Page 15: ... to the equipment is prohibited and shall lead to loss of the operating licence l The use of GSM services SMS messages data communication GPRS etc may lead to additional costs The user alone is responsible for any damages and costs resulting through this l Do not install the device in any other manner than the one described in the operating instructions An improper use will invalidate the warranty...

Page 16: ...echnical data on page 11 must be observed The manufacturer shall not be liable for any operational cases that deviate from these limit values and have not been approved by the manufacturer in writing Note This device is exclusively intended to be used for the purposes as described above Any other use or use beyond what is specified or a modification of the device shall be deemed to be not for the ...

Page 17: ...he device operating time on page 38 using the default configuration 1 channel 200 ms reader type 6 h transmission cycle 4 inputs are available to which a meter contact can be connected without an additional energy supply see Technical details about the meter inputs on page 37 The internal Battery and GSM level measurement values see Internal channels on page 52 are also determined All of the gener...

Page 18: ... During this process all of the data that has not yet been transferred to the myDataweb server is transferred The cables and antenna can be removed as soon as the GPRS connection has been deactivated indicated by the status LED going out see Status LED on page 46 Store the myDatalogNANOamr in its original packaging The battery pack remains in the device The myDatalogNANOamr is placed in energy sav...

Page 19: ...ective equipment and maintenance l the product disposal waste disposal law l the material disposal waste disposal law l the cleaning cleaning agents and disposal l and the environmental protection amendments Before commissioning the operator must ensure that the installation and commissioning provided these were performed by the operator himself are in compliance with the local regulations Rev 01 ...

Page 20: ......

Page 21: ... Client who access the WebApp via a smartphone 4 myDataweb server to which the data is transferred 5 Client that accesses the interface of the myDataweb server via the web browser 6 Customer specific server that provides clients with their own interface The customer specific server obtains the data via the XML interface of the myDataweb server see XML interface on page 75 7 Client on which a PC pr...

Page 22: ...bApp see WebApp on page 65 has a web interface that is optimised for the displays of smartphones making it accessible via these devices However this is only displayed if a Level 1 or 2 user has logged in Users with a higher access level always access the standard web interface even via a smartphone Functions and components provided by the customer l Meter with pulse output Meter that includes a sw...

Page 23: ...and battery measurement values as well as the measurement values of the 4 meter inputs The measurement values for the last thirty minutes are always shown in the ALOHA data window which means that data from a previous ALOHA transmission may be included The ALOHA data is generated every three seconds independently of the normal measurement values and is thus not saved with the standard measurement ...

Page 24: ...ce providers supported by the integrated SIM chip see www microtronics at footprint Note An explanation detailing the conditions when a GSM network is added to the ban list is provided in Ban list on page 24 5 2 1 Ban list The ban list provides space for 5 entries and is not saved in a volatile memory This means that it is also available following a PowerOn If a BEARER GPRS FAILED error occurs see...

Page 25: ... FME 206 801 l BP434RLC 206 725 1 1 The battery pack BP434RLC was already inserted in the myDatalogNANOamr during production Additional accessories such as internal expansions assembly sets antennas accu or battery pack sensors power supply charging devices etc depending on the order Please check these against the delivery slip 6 3 Storage The following storage conditions must be observed myDatalo...

Page 26: ...ory for any returns and can be obtained from the Support Service Centre see Contact information on page 125 The return shipment of the myDatalogNANOamr must occur in the original packaging and with freight and insur ance paid to Microtronics Engineering GmbH see Contact information on page 125 Insufficiently cleared return shipments will otherwise not be accepted 26 Rev 01 ...

Page 27: ...ons must only be performed by qualified personnel 7 1 Dimensions Dimensions Width and height Dimensions Depth 7 2 Installing the myDatalogNANOamr Important note l Ensure the installation is completed properly l Comply with the existing legal and or operational directives l Improper handling can cause injuries and or damage to the devices Rev 01 27 ...

Page 28: ...ive chemicals or gases l Mechanical impacts l Direct installation on foot or road ways l Vibrations l Radioactive emissions Note Approx 15 cm of space should be left beneath the device for the cable connections Further information about the installation dimensions can be found in the relevant sub chapter 7 2 1 Wall mounting For wall mounting the optional Universal bracket for housing myDatanet 86x...

Page 29: ... page 28 If you want to use your own fastening screws you can use the drill guide provided in the equipment set to determine the position of the holes The diameters are then determined by the screws that are being used and any wall plugs that may be required 3 Securing the myDatalogNANOamr to the wall If you want to use the tapping screws 4 included in the equipment set first of all insert the sup...

Page 30: ...of 206 634 1 First attach the assembly loop 3 using the screws 2 included in the DIN rail mounting set for myDatanet housing 86x126 206 634 equipment set to the myDatalogNANOamr see Step 1 of the top hat rail assembly on page 30 2 Place the assembly loop 3 onto the top edge of the top hat rail When turned slightly around the horizontal axis of the myDatalogNANOamr with the assembly loop 3 attached...

Page 31: ...ng kit for myDatanet housing 86x126 206 660 equipment is required for the pipe assembly Step 1 of the pipe assembly Step 2 of the pipe assembly 1 myDatalogNANOamr 3 Assembly loop included in the scope of delivery of 206 660 2 Delta PT M3 5x8 Torx 15 included in the scope of delivery of 206 660 4 Cable binder included in the scope of delivery of 206 660 Rev 01 31 ...

Page 32: ... risks The sensitive electronic components inside the device can be damaged by static electricity which can impair the device performance or even cause the device to fail The manufacturer recommends the following steps to prevent any damage to the device caused by electrostatic discharges l Discharge any static electricity present on your body before handling the electronic components of the devic...

Page 33: ...ts l Run all data cables so that they do not pose a trip hazard and ensure that cables do not have any sharp bends l The myDatalogNANOamr must not be operated in the field with the lid open Connection of the sensors and power supply 1 Antenna connector Cable length 3m 3 Sensor cable with open ends channel 1 and 2 Cable length 1m 2 Sealed sensor cable channel 3 and 4 Cable length 0 12m Channel Colo...

Page 34: ...n against the penetration of moisture can no longer be guaranteed 2 Connect the antenna see Connection of the GSM antenna on page 35 3 Initiate ALOHA transmission mode see ALOHA transmission mode on page 23 The status LED should then start to flicker see Status LED on page 46 indicating that a connection is being established Note If the myDatalogNANOamr is still in transport mode the transport loc...

Page 35: ...ust be used to subtract the backward pulses from the forward pulses 2 The myDatalogNANOamr cannot evaluate type A3 B3 direction signal This connection example can be used if no backward pulses are expected 3 The myDatalogNANOamr cannot evaluate type A4 B4 tamper error signal 7 4 2 Connection of the GSM antenna Important note To ensure the correct functionality only use antennas that are supplied b...

Page 36: ...ences on the signal quality Steel cover up to 30dBm Concrete cover approx 10dBm Environmental influences up to 15dBm Installation height of the antenna approx 5dBm depth of 15 cm Vertical horizontal alignment approx 10dBm Horizontal alignment up to 15dBm Centre edge of the shaft approx 10dBm Other influences Transmission power of the network operator Signal losses compared to the reference measure...

Page 37: ...n case 2 Initiate ALOHA transmission mode see ALOHA transmission mode on page 23 3 Wait until it is indicated in the list of measurement instruments that the device is in ALOHA transmission mode This is indicated by a speech bubble with the Aloha inscription 4 Check the internal GSM level measurement value in the incoming data in the ALOHA data window of the myDataweb server which can be accessed ...

Page 38: ...val on the operating time of the device are detailed in the chapter Technical details about the device operating time see Technical details about the device operating time on page 38 The same sample time is used for all of the inputs This means that the input that requires the longest sample time specifies the sample time The effects on the operating time of the device are insignificant Schematic ...

Page 39: ...active 4 ms reader type 6 h transmission cycle up to 2 83 years 1 channel active 100 ms reader type 6 h transmission cycle up to 3 76 years 2 channel active 100 ms reader type 6 h transmission cycle up to 3 75 years 1 channel active 4 ms reader type 12 h transmission cycle up to 4 64 years 2 channel active 4 ms reader type 12 h transmission cycle up to 4 28 years 1 channel active 100 ms reader typ...

Page 40: ......

Page 41: ...on of the installation Study the manual thoroughly before placing into operation to prevent faulty or incorrect configuration Utilise the manual to familiarise yourself with the operation of the myDatalogNANOamr and the input screens of the myDataweb Server before you begin with the configuration 8 3 Placing the system into operation Note It is recommended that the myDatalogNANOamr is first placed...

Page 42: ... 8 Complete all of the steps detailed in the chapter Connecting the meters on page 33 Important note The last work steps of the chapter Connecting the meters on page 33 include the initiation of ALOHA transmission mode If you intend to install the myDa talogNANOamr in a shaft the device including the antenna should still be outside the shaft when ALOHA transmission mode is initiated 9 Use the WebA...

Page 43: ...e is in ALOHA transmission mode This is indicated by a speech bubble with the Aloha inscription The following steps are only required if you simultaneously want to test the measurement value acquisition and data transmission 6 Stop the ALOHA transmission mode by clicking the cross in the speech bubble with the Aloha inscription or wait for the duration of the ALOHA transmission mode This period ca...

Page 44: ...Note Additional explanation about evaluating the GSM level GSM level 64dBm 64 to 73dBm 74 to 83dBm 84 to 93dBm 94 to 107dBm 108dBm 44 Rev 01 ...

Page 45: ...perating elements 1 Solenoid switch 2 Status LED 9 1 1 1 Solenoid switch The MDN Magnet 206 803 that is available as an accessory is required to operate the solenoid switch The solenoid switch can be used to initiate the ALOHA transmission mode or to instruct the myDatalogNANOamr to immediately issue the error status code Operation by the user Device response Operation after releasing the solenoid...

Page 46: ...by GPRS ON measurement OFF see transport lock 6x Offline GPRS OFF measurement ON see transport lock 7x Network block no matching provider l Improve position of the antenna l Check whether the device is located in the coverage area of a service provider that is supported by the integrated SIM chip www microtronics at footprint 8x No GSM network l Try again later l Improve position of the antenna 10...

Page 47: ...f the site in the list of sites to get to the input screen for configuring the site see myDatanet Server Manual 805002 9 2 1 1 Site Customer Specifies to which customer the site is assigned icon Assign site to another customer Name Site designation not relevant for the device or data assignment 2 50 characters Instrument S N Serial number of the device that is linked to the site device assignment ...

Page 48: ...isplay elements of the server see Additional information on configuring a meter input on page 48 Max Defines the upper scale end of the pointer instruments Unit String which is used as the measurement unit by all of the server display elements The WebApp also uses this string to display the meter readings Decimal places Number of decimal places that are used by all of the server display elements B...

Page 49: ...erval 1ms sample time 40µs Itron CYBLE K1000 64 ms Itron reader Minimum signal length for the signal detection 64 ms sample interval 15 6ms sample time 30µs Itron EMES UNIT 64 ms Sensus HRI 15 ms Sensus reader Minimum signal length for the signal detection 15 ms sample interval 1ms sample time 30µs Sensus HRI Mei 15 ms Sensus OD01 4 ms Sensus reader Minimum signal length for the signal detection 4...

Page 50: ...signal length for the signal detection 4 ms sample interval 1ms sample time 30µs fast plus 4 ms Universal setting for short pulses and high load resistances Minimum signal length for the signal detection 4 ms sample interval 1ms sample time 40µs Colour of the cable Specifies the colours of the pair of wires for the meter input 9 2 1 4 Calculated channels Note The values of the calculated channels ...

Page 51: ...r instruments Unit String which is used as the measurement unit by all of the server display elements Decimal places Number of decimal places that are used by all of the server display elements Shifts element down Shifts element up 9 2 1 4 2 Calculation Off Calculated channel deactivated Table Source Selection of the channel from which the input data is used Opens the screen for entering the value...

Page 52: ...ll of the server display elements 9 2 1 6 Alarm settings Acknowledgement Standard The global server setting is used to determine whether to acknowledge alarms automatically or manually see myDatanet Server Manual 805002 automatic Alarms are acknowledged automatically as soon as all of the messages have been sent If SMS that have a tariff with a delivery confirmation function have also been sent ac...

Page 53: ...cycle parameter Record interval Time between measurement data recordings Time zone Regional settings not relevant for raw measurement data as this is stored in the UTC Daylight saving time Configuration for automatic time adjustment Standard The configuration for the time adjustment is adopted by the global server setting see myDatanet Server Manual 805002 Off Automatic time adjustment deactivated...

Page 54: ...e myDatanet Server Manual 805002 or by clicking on the device name in the device name list see myDatanet Server Manual 805002 9 2 2 1 Comments Comments Empty comment field is also displayed below the site name in the measurement instrument list 9 2 2 2 Measurement instrument Customer Name of the customer to whom the measurement instrument is assigned IMSI IMSI of the used SIM chip or SIM card Seri...

Page 55: ...single firmware update If no new firmware is available or the firmware was installed successfully the firmware update is automatically switched to OFF Firmware type Released Only firmware versions that have successfully undergone internal and field testing are installed this practically eliminates malfunctions Release candidate Only firmware versions that have successfully undergone internal testi...

Page 56: ...9 2 2 4 GPRS SIM tariff Selected SIM tariff 56 Rev 01 ...

Page 57: ...the user that is currently logged in is assigned 7 Switches to the Data exports area to configure the data export This tab is only visible if at least the licence for one export variant is available 4 Opens the screen to input the global settings for the server 8 Opens the input screen to upload a XML file This tab is only visible if the licence for the XML import is available 10 1 1 Explanation o...

Page 58: ...report is accessed by clicking on the name of the customer Otherwise the Sites area at customer level is opened by clicking on the name of the customer see Site area at customer level on page 59 or Reports on page 59 7 Customer s address that can be entered via the input screen for configuring the customer 8 Symbol via which an image file can be loaded on to the server as an Overview map To remove...

Page 59: ...e file beforehand 2 Current Map on which the sites can be placed 3 Symbol that represents a site on the Map 4 List of reports see Reports on page 59 5 List of sites see Site on page 47 10 3 1 Reports The reports provide a variety of options to display graphs of the data on the web interface of the myDataweb server or to download the data from the myDataweb server Detailed instructions on creating ...

Page 60: ...face on the myDataweb server You will receive the web address from your responsible sales partner Login form of the myDataweb server 2 Click on the Customer menu item of the myDataweb server to call up the list of available customers Select an existing customer or create a new customer Selecting the customer 1 Menu item to call up the list of customers 3 List of available customers 2 Creating a ne...

Page 61: ...page 61 or the device is already assigned to a different site More detailed information on this is provided in myDatanet Server Manual 805002 Linking the device and site 1 Device assignment 2 List of devices that have not yet been linked with a site 10 4 2 Assigning a device to the customer Note Some of the fields mentioned in the following chapters may be hidden depending on the respective user l...

Page 62: ...ice to the customer 1 Menu item to call up the list of devices that are in ALOHA transmission mode 4 Opens the dialogue to select the customer to whom the device should be assigned 2 List of devices in ALOHA transmission mode 5 Selection of the customer to whom the device should be assigned 3 Filter for the list of measurement instruments 6 List of measurement instruments 3 Initiate ALOHA transmis...

Page 63: ...lter to find the required device in the list of measurement instruments Click on the symbol to open the dialogue to select the customer see Assigning a device to the customer on page 62 and assign the device to the selected customer Rev 01 63 ...

Page 64: ......

Page 65: ...early identifies the user on the myDataweb server and thus means that the login dialogue can be skipped and direct access to the list of sites is granted A Direct login link can only be created if the Direct login function has been activated for the relevant user see myDatanet Server Manual 805002 and requires the login process to be completed once via the login dialogue The Direct login function ...

Page 66: ...Login dialogue iPhone After you have entered your login details you can access the list of sites Note The Direct login link can only be created from the list of sites 66 Rev 01 ...

Page 67: ...l to open the submenu List of sites iOS Submenu for creating a link Use the Add to home screen button to add a Direct login link as a symbol on your Home screen or use the Add bookmark button to bookmark your Direct login link Rev 01 67 ...

Page 68: ...utton to access the browser s basic menu and then select the symbol to expand the menu List of sites Android Submenu for creating a link Use the Add shortcut to home button to add a Direct login link as a symbol on your Home screen 68 Rev 01 ...

Page 69: ...ite titles 6 Title of the measurement channels 3 Title of the site 7 Position data is not available for the site 4 Serial number of the device linked to the site 8 Indicates that the list of sites is sorted according to titles of the sites Clicking will change the sorting according to distance Sites for which the assigned device is in ALOHA transmission mode see ALOHA transmission mode on page 23 ...

Page 70: ... the list of sites If you are at the site you can use the GPS receiver of your smartphone to assign your current position to the site via the WebApp To do this click on the distance value position data is already available or on the symbol that indicates that there is no position data available yet List of sites Assigning the position 1 Distance value position data is already available 2 No positi...

Page 71: ...f the last measurement value 2 Title of the site 6 Last measurement value meter reading 1 3 GSM signal strength 7 Colours of the pair of wires for the measurement channel 4 Title of the measurement channels 8 Comment on the site 1 The measurement channel is deactivated if no meter reading is displayed It cannot be activated via the WebApp but can only be activated via the standard web interface se...

Page 72: ...te info screen on page 71 In this case the background colour will also indicate the connection status green for ALOHA transmission mode blue for offline of the device connected to the site Changes cannot be made in offline mode Which of the input fields can be edited in ALOHA transmission mode is dependent on the authorisation level of the user who is logged in Screen for configuring a measurement...

Page 73: ...ir of wires for the measurement channel 1 The measurement channel is deactivated if no meter reading is displayed It cannot be activated via the WebApp but can only be activated via the standard web interface see Measurement channels on page 48 2 Can only be edited via the standard web interface see Measurement channels on page 48 3 The input fields can only be edited when the myDatalogNANOamr is ...

Page 74: ...ype and title of the measurement channel in addition to the pulse value and the meter reading Screen for configuring a measurement channel ALOHA level 2 1 Input field to change the meter reading can only be edited when the measurement channel is activated 4 Input field to change the title of the measurement channel 2 Selection of the reader type see Config on page 49 5 Button for accepting the con...

Page 75: ...ver In this case contact your responsible sales partner 12 1 General The XML interface is provided to export data from and import data to the myDataweb server However this is not just limited to the pure measurement data but includes all of the data provided by the myDataweb server e g measurement data configurations log entries alarm lists etc It is therefore possible for the customer to complete...

Page 76: ...vice Device log see mydatalognanoamr_aloha on page 91 mydatalognanoamr_user1 Site User config 1 see mydatalognanoamr_user1 on page 89 mydatalognanoamr_state Device Device status see mydatalognanoamr_state on page 91 mydatalognanoamr_aloha Device Aloha data see mydatalognanoamr_aloha on page 91 mydatalognanoamr_pos Device Position and network information see mydatalognanoamr_pos on page 91 mydatalo...

Page 77: ... adjustment is adopted by the global server setting OFF Automatic time adjustment deactivated USA 99CC96152B000000 Predefined setting for the American area EU 99CC95A627080884 Predefined setting for the European area alert_mode Setting for acknowledging the alarms Value Explanation 0 The global server setting is used to determine whether to acknowledge alarms automatically or manually 1 Alarms are...

Page 78: ... which the transfer volume alarm should be triggered KB max_transfer_volume_kb This is a Ghost field the content of which always corresponds to that of the max_transfer_ volume field comment Free comment field is also displayed below the device type in the site list loc_site_lat Specification of the geographical latitude where the site is located loc_site_long Specification of the geographical lon...

Page 79: ...ipients parallel alarm call plan type and or the first recipient serial alarm call plan type as soon as this page is saved The check box is subsequently reset automatically scale_units1 scale_units4 String that the WebApp displays as the measuring unit when specifying the pulse value see Configuring the measurement channels on page 72 0 16 characters scale_factor1 scale_factor4 Factor with which t...

Page 80: ...wire_color1 wire_color4 Specifies the colours of the pair of wires for the meter input read only 80 Rev 01 ...

Page 81: ...taweb server The sample time that must be used for the relevant reader type is specified in the chapter Config on page 49 As the same sample time is used for all meter inputs the longest of the required sample times must be entered in the mydatalognanoamr_ user1 table Value Explanation 0 slow 200 ms 1 medium 64 ms 2 fast 4 ms 3 fast plus 4 ms 10 Elster Grey Snapfit 4 ms 11 Elster Black Snapfit 4 m...

Page 82: ... the Overview map The following parameters apply to the Meter inputs see Measurement channels on page 48 title1 title4 Freely selectable channel title for the meter inputs units1 units4 String which is used as the measurement unit by all of the server display elements max_max1 max_max4 Defines the upper scale end of the pointer instruments decpl1 decpl4 Number of decimal places that are used by al...

Page 83: ...per scale end of the pointer instruments decpl60 decpl64 Number of decimal places that are used by all of the server display elements Value Explanation 1 Standard 0 No decimal places 6 6 decimal places alarm_low60 alarm_low64 An alarm is initiated if the measurement value drops to or below this value alarm_high60 alarm_high64 An alarm is initiated if the measurement value meets or exceeds this val...

Page 84: ...wakeup read only lastdisc Time stamp of the last disconnection read only lasterr Time stamp of the last transmission error read only lastaloha Time stamp of the last Aloha connection read only fw_update Settings for the firmware update Value Explanation 0 Off Firmware update is deactivated 1 On As soon as a new version of the selected firmware type is available this is installed immediately 2 Even...

Page 85: ...d geraet Unique data record number of the device to which the connection list is assigned text Duration of the connection context Title of the site with which the device is linked or error that occurred during the connection source Serial number and IP address cmh_quantity Amount of received data in bytes device to the server cmh_quantity2 Amount of sent data in bytes server to the device cmh_code...

Page 86: ...e of the ERP codes that was created via the global server settings see myDatanet Server Manual805002 Important note If an invalid code is specified the ERP code is set to the global server settings the next time you edit the customer via the web interface of the myDataweb server sms_enabled This includes the option to generally deactivate SMS for the customer Value Explanation 1 The setting is ado...

Page 87: ...ledged by the user Value Explanation 0 The setting is adopted from the global server settings 1 Inform about every alarm per site In this case the alarm schedule is activated every time an alarm is triggered Even if the alarm schedule has already been executed and the alarm has not yet been acknowledged the alarm schedule is executed again if a new alarm is triggered on the site Important note Thi...

Page 88: ...ery voltage V battery Battery voltage calculated based on the battery voltage in Volt 12 2 2 2 mydatalognanoamr_channel This table includes the configuration of the meter inputs see Measurement channels on page 48 that is transferred to the myDatalogNANOamr context Unique data record number of the site read only mode1 mode4 Basic settings for the measurement channel Value Explanation 0 Measurement...

Page 89: ...ation Parameter mydatalognanoamr_channel Value scale1 0 005000 filter_time1d filter_time4d Minimum signal length for signal detection ms 12 2 2 3 mydatalognanoamr_log This table includes the log entries and error codes see Log entries and error codes on page 114 of the device log Log entry par Parameter for the log entry 12 2 2 4 mydatalognanoamr_user1 This table includes the remaining configurati...

Page 90: ... the transmission cycle alive_time Aloha Wakeup duration connection 00 60 90 00 mm ss switch_mode Operation that is triggered when the solenoid switch is activated read only Value Explanation 1 Initiation of ALOHA transmission mode tx_time Time at which the device establishes a connection to the server regardless of the transmission cycle However this additional transmission is only completed if a...

Page 91: ... last connection net_mnc MNC mobile network code of the network that was used for the last connection imei IMEI of the modem sim_icc_id ICC ID of the SIM chip 12 2 2 6 mydatalognanoamr_aloha This table includes the ALOHA data that is generated every three seconds independently of the normal measurement values and is thus not saved with the standard measurement data see ALOHA transmission mode on p...

Page 92: ... country 100 Position could be calculated from the information of the GSM cells in the receiving range 31 000 Position determined by the GPS receiver1 1 The myDatalogNANOamr does not include a GPS receiver Information about the five GSM cells in the receiving range that were used to determine the position gsm_mcc_0 gsm_mcc_4 MCC mobile country code of the GSM cell gsm_rssi_0 gsm_rssi_4 Received GS...

Page 93: ...ne URL is assembled as follows and provides an XML document as a result https IP address Port XPath Query login settings update Parameter Explanation IP Address Address of the server on which the xPath module operates myDataweb server Port Port on which the xPath server operates The standard setting is 8080 xPath Query xPath of the required XML table e g Structure of the database on page 75 A desc...

Page 94: ...Last disconnection units data locals time_code nbsp data locals offset_record lastdisc lastdisc Field Field title Last transmission error units data locals time_code nbsp data locals offset_record lasterr lasterr Field Field title Last Aloha connection units data locals time_code nbsp data locals offset_record lastaloha lastaloha Field Field title Firmware update fw_update Field Field title Firmwa...

Page 95: ...que data record number stamp Time stamp of the data record only operator and are permitted ref Unique data record number of the reference data record The following operators are supported The following types can be used as constants Data type Explanation Integer Whole numbers Float Floating point numbers Strings Text indicated by single inverted commas Date Time stamp within single inverted commas...

Page 96: ...0 stamp 8 2 2013 11 48 16 tag FFFF6000 tag name title Name site1 name mydatalognanoamrid Result 12 3 1 1 4 Fields If more than one field is read out the list of fields must be placed in round brackets and separated by a or blank space If none of the fields are specified all of the available fields are issued if this is permitted by the user s authorisation level Note The special tag field can be r...

Page 97: ... site that is called Site1 https server URL 8080 mydatalognanoamrid name Site1 mydatalognanoamr_data 0 user u1 password p1 Result Result measurement_values id F10001C000000000 stamp 9 4 2013 09 30 00 tag 00006000 tag context title Site A19D60AC2883F9B3 context flags title Flags 0000000000000000 flags ch1 title Meter number 1 units m 0 0000 ch1 ch2 title Meter number 2 units m ch3 title Meter numbe...

Page 98: ...tle Flags 0000000000000000 flags ch1 title Meter number 1 units m 0 0050 ch1 ch2 title Meter number 2 units m ch3 title Meter number 3 units m ch4 title Meter number 4 units m ch5 title Channel 5 units m calc60 title Flow rate 1 units calc 1 calc61 title Flow rate 2 units calc 1 calc62 title Flow rate 3 units calc 1 calc63 title Flow rate 4 units calc 1 calc64 title Calculation channel 5 units cal...

Page 99: ...bove provides three different results for the values of channel 0 compressed over 15 min l ch0 method 1 Minimum within the compression period l ch0 method 2 Maximum within the compression period l ch0 method 16 sum_mode 4 Daily total over the compression period Based on The value of channel 0 increases by one per minute Result record stamp 2013 01 25 11 30 00 ch0_min 0 0 ch0_min ch0_max 14 0 ch0_m...

Page 100: ...rded in m3 h the total period equals m3 5 1 day e g One channel is recorded in m3 day the total period equals m3 4 Total of a day counter counting channel is reset once per day 6 Total of an interval counter counting channel is reset after each recording 12 3 1 3 Updating data fields A HTTP GET command can also be used to update the fields of a data record For this purpose the HTTP GET command mus...

Page 101: ...raetid devsn 010146AF251D0BA9 user u1 password p1 fw_update 0 Result Result updated 1 updated Result Explanation geraetid Specifies that the entry point for the request is the device table devsn 010146AF251D0BA9 Specifies that the action should apply to the device with serial number 010146AF251D0BA9 fw_update 0 Specifies that the Firmware update should be set to Off 12 3 2 Format of the XML result...

Page 102: ...526911CF1A42CC stamp 13 2 2013 09 33 54 geraetid Result 12 4 XML import The XML import is designed to import the data generated or changed via the user interface created by the customer back into the myDataweb server l Only existing measurement data and settings can be changed or new measurement data can be added No historical measurement data can be added l It must be ensured that the stamp of th...

Page 103: ...ransferred with this POST command The configuration of these is described in the chapter Structure of the XML file on page 104 Parameter Explanation IP Address Address of the server to which the data should be transferred myDataweb server Port Port on which the HTTP server is running Standard value is 80 login The direct login parameter clearly identifies the user on the server Each relevant user ...

Page 104: ...2 4 3 2 Importing data The id 0 attribute must be specified if a new data record is going be created The time stamp for the data record can be determined using the stamp attribute It must be ensured that the time stamp of the data is always in ascending order The stamp attribute can also be omitted In this case the current time is used as the time stamp for the data record The default values of th...

Page 105: ...nt table identifier id id 0 must always be specified when importing data A new data record with an automatically generated ID is created stamp OPTIONAL Time stamp that should be used for the data record It must be ensured that the time stamp of the data is always in ascending order If the attribute is omitted the current time is used as the time stamp for the data record ch1 The actual measurement...

Page 106: ......

Page 107: ...ical damage l Check all of the connections for leaks or corrosion on a regular basis l Check all of the cables for mechanical damage at regular intervals l Clean the myDatalogNANOamr with a soft moist cloth Use a mild cleaning agent if necessary 13 2 Replacing the battery pack Important note When replacing the battery pack under adverse weather conditions or site locations where water can enter fr...

Page 108: ...ssion mode using the magnetic contact see ALOHA transmission mode on page 23 and then check again that all of the relevant data has been transferred 2 Remove the four screws that secure the housing cover and open the myDatalogNANOamr 3 Disconnect the connector of the battery pack from the device s supply connector Important note Avoid excessive force and pull the connector of the battery pack as s...

Page 109: ...connection cable You can then simply remove it in an upwards direction see Removing the battery pack step 2 on page 109 Note Ensure that the battery pack is disposed of in line with environmental require ments Used battery packs can be returned to the manufacturer or handed in at suit able collection points Removing the battery pack step 1 Removing the battery pack step 2 Rev 01 109 ...

Page 110: ...tory 7 Check whether the connection to the myDataweb functions correctly see Testing com munication with the device on page 43 8 Close the housing cover The best option is to tighten the four screws crosswise torque 0 5Nm so that the housing cover is positioned evenly Important note Ensure that the seals are clean and intact before closing the housing cover Remove any impurities and or dirt The ma...

Page 111: ...h the locally valid environmental regulations for electronic products Rechargeable batteries and or battery packs may not remain in the myDatalogNANOamr after dis charging Ensure that the used rechargeable batteries and or battery packs are disposed of in an environmentally proper way Rev 01 111 ...

Page 112: ......

Page 113: ...ch is indicated by a time out entry in the connection list see myDatanet Server Manual 805002 Solution Initiate a ALOHA transmission or wait for the next cyclical transfer l The assignment of the device and site is not correct see Site on page 47 Data at the meter input is not plausible l Check the cable connections see Connecting the meters on page 33 l Check whether the meter input configuration...

Page 114: ...a faulty connection The parameter indicates how many consecutive connections have not worked 1252 MODEM TO CON Timeout while a connection is being established The parameter includes a counter that indicates how many consecutive connection attempts have not worked 1281 ZLIB STREAMPROCESS ERR Internal error Contact the manufacturer if the device log includes the error several times see Contact infor...

Page 115: ... If the ALOHA transmission mode is initiated the myDatalogNANOamr switches back into RUN mode GPRS ON measurement ON 5 TRANSPORT Transport lock GPRS OFF measurement OFF see Standby 6 OFFLINE Offline GPRS OFF measurement ON see Standby 7 NO NET NET LOCK Netlock no matching provider l Try to improve the position of the antenna l Check whether the device is in the coverage area www microtronics at fo...

Page 116: ...1 2 STATE 1 2 11 IP ERROR No myDataweb server available l Check whether port 51241 is enabled on the myDataweb server l Try again later 12 SIM CARD ERROR Faulty SIM chip Contact support 2000 MODULE ERR Reserved for extensions 3000 3099 Reserved for extensions 116 Rev 01 ...

Page 117: ...rage area www microtronics at footprint BEARER GPRS FAILED 988 GPRS setup failure l Try to improve the position of the antenna l Check whether the device is in the coverage area www microtronics at footprint BEARER PPP LCP FAILED 987 Error when negotiating the LCP Internal error BEARER PPP AUTH FAILED 986 Error occurred during PPP authentication Internal error BEARER PPP IPCP FAILED 985 Error when...

Page 118: ...BAD STATE 979 The carrier was not stopped Internal error BEARER DEV 978 Error occurred during link layer initialisation Internal error BEARER GPRS START UNKNOWN 977 Internal error Error when disconnecting the GPRS connection 1200 BEARER GPRS STOP BAD HDL 976 Invalid handling Internal error BEARER GPRS STOP UNKNOWN 975 Internal error 1200 NETLOCK FAILURE 970 Error when selecting the network l Check...

Page 119: ...y again later CHANNEL CSTATE 964 The channel is not in the WIP_CSTATE_ READY state Try again later CHANNEL NOT SUPPORTED 963 The option is not supported by the channel Try again later CHANNEL OUT OF RANGE 962 The optional value is outside the permissible range Try again later CHANNEL MEMORY 961 Internal error CHANNEL INTERNAL 960 Internal error CHANNEL INVALID 959 Invalid option or parameter Inter...

Page 120: ...e device log on the myDataweb server The last 300 log entries on the myDataweb server can be called up via the button shown below that is located in the measurement device list As the log entries are sent to the server in the transmission cycle in the same way as the measurement data only the log entries up to the last server connection are available The manual for the server myDatanet Server Manu...

Page 121: ... Smart Disc FME F 1 206 814 Extension cable for Antenna 900 FME 1 206 805 Flat Antenna Smart Disc US FME F 1 206 817 Antenna 1800 FME 1 206 809 antenna adapter FME F to SMA F 1 206 822 flat antenna Smart Disc Plus FME F 1 206 824 antenna extension SMA F to FME F 1 206 825 Flat whip antenna with adapter SMA FME 1 206 830 Portable Antenne Multi Band 1 206 826 16 3 Battery packs Description Quantity ...

Page 122: ......

Page 123: ...Chapter 17 Document history Chapter 17 Document history Rev Date Changes 01 26 04 2013 First version Rev 01 123 ...

Page 124: ......

Page 125: ...756 7718023 support microtronics at www microtronics at Microtronics Engineering GmbH Headquarter Hauptstrasse 7 3244 Ruprechtshofen Austria Europe Tel 43 0 2756 77180 Fax 43 0 2756 7718033 office microtronics at www microtronics at Microtronics Engineering GmbH Windthorststrasse 5 63179 Obertshausen Germany Europe office microtronics de www microtronics de Rev 01 125 ...

Reviews: