transfer_alerts
Alarm in the event that the device does not respond for longer than the set transmission cycles
Value
Explanation
0
No alarm settings
1
standard (>2x transmission cycles)
2
immediately (>1x transmission cycle)
3
medium (>5x transmission cycles)
4
long (>10x transmission cycles)
5
extra long (>20x transmission cycles)
max_transfer_volume
Settings for the transfer volume alarm
Value
Explanation
-1
The configuration for the transfer volume alarm is adopted from the global server
setting
0
The transfer volume alarm is deactivated.
> 0
Threshold at which the transfer volume alarm should be triggered [KB]
max_transfer_volume_kb
This is a "Ghost" field, the content of which always corresponds to that of the "max_transfer_
volume" field.
comment
Free comment field (is also displayed below the device type in the site list)
loc_site_lat
Specification of the geographical latitude where the site is located [°]
loc_site_long
Specification of the geographical longitude where the site is located [°]
loc_alarm_rad_mode
A radius can be defined for a site. Depending on the settings for this parameter, an alarm is
triggered if the device leaves this radius.
Value
Explanation
0
Radius monitoring deactivated (no alarm)
> 0
Specification of the alarm radius [km]. An alarm is triggered if the device leaves the
radius.
78
Rev. 01
Summary of Contents for myDatalogNANOamr
Page 2: ......
Page 9: ...Chapter 2 Declaration of conformity Chapter 2 Declaration of conformity Rev 01 9 ...
Page 10: ......
Page 12: ......
Page 20: ......
Page 40: ......
Page 56: ...9 2 2 4 GPRS SIM tariff Selected SIM tariff 56 Rev 01 ...
Page 64: ......
Page 106: ......
Page 112: ......
Page 122: ......
Page 124: ......