Aquamaster (8 ms)
Aquamaster reader
Minimum signal length for the signal detection: 8 ms
sample interval: 1ms
sample time: 30µs
slow (200 ms)
Universal setting for long pulses:
Minimum signal length for the signal detection: 200 ms
sample interval: 15,6ms
sample time: 30µs
medium (64 ms)
Universal setting for medium pulses:
Minimum signal length for the signal detection: 64 ms
sample interval: 15,6ms
sample time: 30µs
fast (4 ms)
Universal setting for short pulses:
Minimum signal length for the signal detection: 4 ms
sample interval: 1ms
sample time: 30µs
fast plus (4 ms)
Universal setting for short pulses and high load resistances:
Minimum signal length for the signal detection: 4 ms
sample interval: 1ms
sample time: 40µs
Colour of the cable
Specifies the colours of the pair of wires for the meter input
9.2.1.4 Calculated channels
Note: The values of the calculated channels are calculated directly for the data output (display on myDataweb
server or download from myDataweb server). They are not saved in the server database.
9.2.1.4.1 Basis
Title 1-5
Freely selectable channel title for the calculated channels [0-16 characters]
50
Rev. 01