context
Unique data record number of the site (read only)
measure_mode
Operating type
Value
Explanation
0
HOLD
Measurement: OFF, transmission: ON
1
RUN
Measurement: ON, transmission: ON
2
OFF
Measurement: OFF, transmission: OFF
3
OFFLINE
Measurement: ON, transmission: OFF
4
Reserved for internal use
record_interval
Time between measurements (00:00 same as record interval) [1...1090min]
transfer_interval
Time between transmissions [00:10...168:00 hh:mm]
pos_cycle
Position update interval [00:00...168:00 hh:mm]
tx_mode
Connection type (read only)
Value
Explanation
0
The device registers in the transmission cycle.
alive_time
Aloha/Wakeup duration connection[00:60...90:00 mm:ss]
switch_mode
Operation that is triggered when the solenoid switch is activated, (read only)
Value
Explanation
1
Initiation of ALOHA transmission mode
tx_time
Time at which the device establishes a connection to the server regardless of the transmission
cycle. However, this additional transmission is only completed if a transmission has not
already been completed 5 minutes before this time or if a transmission will not be completed
10 minutes after this time.[hh:mm]
sample_time
Sample time for which the output voltage U
out
is activated during the sample interval to
determine the levels at the meter inputs (see "Technical details about the meter inputs" on
page 37) [30...1000µs].
90
Rev. 01
Summary of Contents for myDatalogNANOamr
Page 2: ......
Page 9: ...Chapter 2 Declaration of conformity Chapter 2 Declaration of conformity Rev 01 9 ...
Page 10: ......
Page 12: ......
Page 20: ......
Page 40: ......
Page 56: ...9 2 2 4 GPRS SIM tariff Selected SIM tariff 56 Rev 01 ...
Page 64: ......
Page 106: ......
Page 112: ......
Page 122: ......
Page 124: ......