Chapter 7 Installation
Note: It must be noted that if the transport lock is activated, the myDatalogNANOamr uses a
certain, albeit low, amount of energy even during storage. This means that if a device has
already been stored for a prolonged period that the operating times in the following table
might not be able to achieved anymore.
Configuration
Device operating time
1 channel active
4 ms reader type
6 h transmission cycle
up to 3 years
2 channel active
4 ms reader type
6 h transmission cycle
up to 2,83 years
1 channel active
100 ms reader type
6 h transmission cycle
up to 3,76 years
2 channel active
100 ms reader type
6 h transmission cycle
up to 3,75 years
1 channel active
4 ms reader type
12 h transmission cycle
up to 4,64 years
2 channel active
4 ms reader type
12 h transmission cycle
up to 4,28 years
1 channel active
100 ms reader type
12 h transmission cycle
up to 6,87 years
2 channel active
100 ms reader type
12 h transmission cycle
up to 6,81 years
Important note: Any deviation of the configuration from the values in the table affect the
operating time of the device.