Chapter 8 Initial Start-Up
Note: Information on improving the reception quality is provided in chapter "Optimum antenna posi-
tioning for assembly in a shaft" on page 36.
8.4 Testing communication with the device
1. Create a site for the operation on the myDataweb server (see "myDatanet Server Manual"
805002).
2. Configure the created site according to your requirements (see "Site configuration" on page
47).
3. Link the myDatalogNANOamr with the created site (see "Site" on page 47).
4. Initiate the ALOHA transmission mode (see "ALOHA transmission mode" on page 23) so that
the configuration of the site is transferred to the myDatalogNANOamr .
5. Wait until it is indicated in the list of measurement instruments that the device is in ALOHA
transmission mode. This is indicated by a speech bubble with the "Aloha" inscription.
The following steps are only required if you simultaneously want to test the measurement value
acquisition and data transmission.
6. Stop the ALOHA transmission mode by clicking the cross in the speech bubble with the
"Aloha" inscription or wait for the duration of the ALOHA transmission mode. This period can
be set in the basic settings (see "Basic setting" on page 53) of the site configuration. The
default setting is 10 minutes.
7. Then wire up the sensors (see "Connecting the meters" on page 33) and restart the ALOHA
transmission mode.
8. Check the incoming data in the ALOHA data window of the myDataweb server, which can be
accessed by clicking on the speech bubble with the "Aloha" inscription (see "myDatanet
Server Manual" 805002). Particular attention must be paid to the internal"GSM level" meas-
urement value.
Rev. 01
43
Summary of Contents for myDatalogNANOamr
Page 2: ......
Page 9: ...Chapter 2 Declaration of conformity Chapter 2 Declaration of conformity Rev 01 9 ...
Page 10: ......
Page 12: ......
Page 20: ......
Page 40: ......
Page 56: ...9 2 2 4 GPRS SIM tariff Selected SIM tariff 56 Rev 01 ...
Page 64: ......
Page 106: ......
Page 112: ......
Page 122: ......
Page 124: ......