Operator’s Manual 

 
Installation Instructions 
 
 

KACO-proLOG  M / XL 

 

Summary of Contents for proLOG M

Page 1: ...Operator s Manual Installation Instructions KACO proLOG M XL...

Page 2: ...ents 13 6 2 Connection to KACO proLOG with Ethernet M and XL 13 6 3 Connecting to KACO proLOG with modem 13 6 3 1 Windows 95 98 14 6 3 2 Windows 2000 16 6 3 3 Windows XP 18 6 4 KACO Web Optional 21 7...

Page 3: ...l local regulations and provisions must be observed when operating this device Damaged instruments must be made inoperable immediately and or checked by authorized skilled personnel Manipulating or mo...

Page 4: ...appropriate place of installation The KACO proLOG data logger should be installed in the vicinity of a telephone or Ethernet connection and 110V mains connection To avoid damage of your KACO proLOG da...

Page 5: ...ne The data loggers are equipped with an internal modem analog or ISDN The required cable connection is included in the scope of delivery 4 4 4 24V external rear port This port ensures the supply of e...

Page 6: ...r voltage measurements ranging from 0 10V In addition direct connection of a PT 1000 temperature sensor is enabled The device has to be configured accordingly also please refer to 6 4 PVIweb optional...

Page 7: ...nnections Important details on how to establish Ethernet connections are given under 4 1 4 Ethernet Step 3 Switching on the KACO proLOG Enable supply voltage the Power LED must be permanently ON after...

Page 8: ...d for such entries as the IP address of the Web log or for searching inverter types In addition the current measuring values and stored energy yields can be retrieved during operation Navigating throu...

Page 9: ...5 3 3 Structure of the display menu KACO SOLAR INC 9 Operator s Instructions KACO proLOG...

Page 10: ...been selected Network mask Indicates the network mask being used unless another mask is assigned by the BOOTP or DHCP server Gateway Indicates the gateway being used unless another assignment has bee...

Page 11: ...vious day s energy yield Monthly energy yield Annual energy yield Total energy yield y Inverter energy If inverters are selected for the calculation of installation output and energy yield the respect...

Page 12: ...bmenu No Dialtone the device is unable to receive an external exchange line No Carrier Modem has lost or not recognized its carrier signal No Answer The called number does not answer Busy The called n...

Page 13: ...stem control of your PC KACO proLOG must be addressed with the correct IP address and network mask The standard IP address is 192 168 100 50 with a network mask of 255 255 255 0 This means that KACO p...

Page 14: ...m with analog simulation must be used for communication If KACO proLOG is equipped with an internal ISDN modem the PC must likewise be equipped with an internal ISDN modem for communication Step 3 Cli...

Page 15: ...re commands for the telephone system wait until external call prefix is established More detailed information is given in the description of the telephone system Step 5 After establishing the connecti...

Page 16: ...connected to your PC and installed If KACO proLOG is equipped with an internal analog modem an analog modem or ISDN modem with analog simulation must be used for communication If KACO proLOG is equipp...

Page 17: ...ers between the digits of the telephone numbers are commands for the telephone system wait until externall call prefix is established More detailed information is given in the description of the telep...

Page 18: ...u item network connections Now select Assistant for new connections If KACO proLOG is equipped with an internal analog modem an analog modem or ISDN modem with analog simulation must be used for commu...

Page 19: ...number of KACO proLOG The next dialog can be used to enter a user name of your choice under User The Password fields may remain blank NOTE The checkboxes 2 Standardconnection and 3 Internet Connectio...

Page 20: ...fter successful buildup of the connection the dialog Connect to will be opened In this dialog first press Features In the next dialog change to the Network tab and click Internet Protocol TCP IP follo...

Page 21: ...established More detailed information is given in the description of the telephone system Step 5 After successful buildup of the connection the browser is opened e g Netscape 6 1 and the IP address o...

Page 22: ...s in this field may result in malfunctions of the data logger Please do not enter any changes without prior consultation with the administrator or KACO SOLAR INC 7 1 General information The start page...

Page 23: ...0 kW 4 Meter 4 0 000 0 000 0 000 kW 2 050 kW This box shows the measured values separately for each digital input Current output The metering pulses are converted to the respective output value displa...

Page 24: ...iterion Status Indicates if the criterion is defined as active or inactive Upper limit Shows the current upper limit of the monitoring criterion Actual value Shows the actual value of the monitoring c...

Page 25: ...y Used for calculating the alarm criteria Number of subsystems Used for calculating the alarm criteria Storage interval Data compression to 300 600 900 1800 3600 sec Orientation Provides information a...

Page 26: ...arm criteria plant messages or plant parameters Company contact person This entry is used to designate the contact It is shown in the fields that define where an alarm message is addressed to y Street...

Page 27: ...adapter settings refer to the ISDN settings of KACO proLOG If the device is to be used at an ISDN extension you must enter the appropriate extension number MSN Number of the ISDN extension usually a...

Page 28: ...face If emails are to be sent via the local network e g via DSL no provider must be selected from the list on the left Match with database server Yes No If the KACO web service is used all alarm messa...

Page 29: ...arm has occurred already Current info Shows how often the last alarm was triggered Reset The Reset Counter button is used to reset the alarm counter 7 5 5 Inverters This field can be used to enter set...

Page 30: ...alarm is re activated if the measuring for this time interval y Number of triggered alarms Indicates the number of registered alarm The following functions are differentiated under Formula Settings y...

Page 31: ...in seconds depending on the pulse frequency y Meter reading Indicates the current reading of the energy measurement this value may also be entered manually 7 6 3 Current sensors This field is used to...

Page 32: ...t Input The formula to convert the measured calculating value into a physical value is as follows Offset phys Gradient MW Value hannel MeasuringC FinalValue ange MeasuringR FinalValue phys Gradient al...

Page 33: ...ch St rmeldung obere Gernz berschreitung St rmeldung untere Gernz berschreitung To gain more freedom and flexibility when selecting a range two different gradients can be defined The shift of the stra...

Page 34: ...r once per day In the field formula settings enter the daily yield abbreviation of the respective inverter under x y In our example this is EINV_3 E_INV4 The shift of addresses results from the fact t...

Page 35: ...perature Collector Part 1 T_K1 C DC current I_DC_0 A DC current Plant Section 1 I_DC_1 A DC current Plant Section 2 I_DC_2 A DC current Plant Section 3 I_DC_3 A DC voltage U_DC_0 V DC voltage Plant Se...

Page 36: ...3 RS 485 Mechanical Data Dimensions WxHxD 230 x 225 x 85mm Installation Wall mounted Protection Class IP21 Weight 1 kg Battery A lithium cell of the type Li2032 is used as battery This battery can be...