SPECIFICATIONS
Temperature Range: 

WTDL-10/WTDL-20  -4 to 176°F (-20 to 80°C)  WTDL-30

-328 to 500°F (-200°C TO 260°C) for probe

Humidity Range:

WTDL-20  0 to 95% RH

Temperature Accuracy: 

WTDL-10/WTDL-20  0 9°F (0 5°C) from 32 to 122°F (0

to 50°C)  WTDL-30  0 18°F (0 1°C) from -4 to 176°F (-20 to 80°C)  0 9°F (0 5°C)
outside of specified range

Humidity Accuracy: 

WTDL-20  ±3 0% RH  ±2% typical at 77°F (25°C)

Temperature Resolution:

0 018°F (0 01°C)

Humidity Resolution:

WTDL-20 only  0 1% RH

RF Carrier Frequency: 

2 45 GHz

Band: 

SM band 2 405-2 48 GHz

Maximum Power Output: 

+0 dBm typical

Wireless Transmission Range: 

2000´ (610 m) outdoors  line of sight  500´ (152

m) indoors

Receiver Sensitivity: 

-95 dBm typical

Memory Size: 

WTDL-10/WTDL-30  30 000 Readings  WTDL-20  15 000

readings per channel  software configurable memory wrap

Sampling Method:

Stop on memory full or continuous recording

Sampling Rate: 

2 sec to 24 hrs

Temperature Limits: 

-4 to 176°F (-20 to 80°C)

Humidity Limits:

0 to 95% RH

Computer Requirements: 

Windows

®

Xp Sp3  Windows Vista

®

Windows

®

7

Computer Interface: 

WTDL-RX

Power Requirements: 

3 6 V TL-5104 lithium metal battery  installed functional

user replaceable

Battery Life: 

2 years (approx )

Housing Material:

ABS plastic

Weight:

0 25 lb (113 4 g)

FCC Approval:

FCC  D# OA3MRF24J40MA

Agency Approvals: 

CE

The Series WTDL Temperature/Humidity Data Logger

is perfect for applications

which  require  real  time  monitoring   or  in  areas  that  are  not  as  accessible  to
periodically  retrieve  the  loggers   The  data loggers  can  transmit  up  to 500  feet
indoors  and  up  to 2000  feet  outdoors  The  distance  can  be  increased  by  using
additional receivers  Wireless data is transmitted on a 2 4 GHz frequency allowing
it to be used anywhere in the world  A network of data loggers can be separated
into a  smaller  subnet  These  subnets can  all  be  controlled  by  a  single  PC The
Series WTDL data loggers also feature a user programmable alarm  This alarm
can be configured to show an on screen alarm  send a text message (standard
SMS rates apply) or an email if an alarm condition is met

SOFTWARE INSTALLATION

1   nsert installation software and click install Dwyer 2 00

2  Follow on screen instructions
3  Next  click on the  nstall USB nterface Drivers on the CD contents screen
4  Click  nstall
5  Next  click on  nstall RFLogNET on the CD contents screen
6  Click  nstall

Figure 1: Software/Driver Installer

Windows

®

and Windows Vista

®

are registered trademarks of Microsoft Corporation

O

3/8

[9.40]

1-17/64

[32.00]

PROBE

ATTACHMENT

WHITE

BODY

4-61/64

[125.72]

27/64

[10.67]

180° HORIZONTAL

ROTATION

90° VERTICAL

ROTATION

5.296

.120

3.780

2.753

.760

Ø.137 X 2

3.580

.600

MINI USB

PORT

1.570

2.753

3.575

.300

WTDL-30

Wireless Transceiver 

WTDL-10/20

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176