MA-5195-ENG
PS20 NON STOP+ DRUM UNLOADER MANUAL
MELTER OPERATION
4-27
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
10 min
85 °C
60 s
Modbus
B: 57600
Node: 10
2.2 Extra Settings
Inside device temperature alarm
Pumping autolock
Screen saver
Sound on alarm
OFF after reset
2.2 Extra settings
• Activate or deactivate the alarm sound.
To stop the sound, press the
ALARM icon on the HOME screen.
• Activate or deactivate the screensaver.
The screen switches off after the
set time has passed. If you press the screen when it is off, it turns on and
the HOME menu appears.
• Cabinet temperature alarm:
A value (+°C/°F) and a time are defined to
indicate when the alarm is activated due to overheating inside the unit’s
electrical cabinet. If it reaches this temperature and maintains it for the set
time, the unit disconnects the heating of all zones and stops the pumping.
• Automatic pumping block.
Please see the ‘Automatic pumping block
function’ section.
• Turning off after resetting.
Please see the ‘Turning off after resetting
function’ section.
• Modbus.
Activate and disable external communications via Modbus.
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
6
2.2 Extra Settings
Liquid charger
Channel number
Minimum level sensor
Regrid charger
Cover detector
Gas injection
Feeder
Pattern controller
External HMI
Wireless communication
• Number of channels.
Set up the number of electrical outputs enabled in
the melter.
• Automatic feeder.
Activate or disable the operation of the automatic
feeder.
• Feeder.
Activate or disable the operation of the external adhesive feed
(external liquid load or pellet level).
• Pattern controller.
Activate or disable the pattern controller functions.
• Level sensor.
Activate or disable the operation of the level sensor.
• External HMI.
Activate or disable the operation of the external HMI
control.
• Wireless communications.
You can enable or disable the operation of the
unit’s wireless communication system (Wi-Fi). Click on the arrow to go to
the configuration screen. See the point on ‘Wireless communications’ for
further information.
If you try to access a restricted menu, a pop-up appears, requesting the
password.
If the EXPERT password is entered, the unit remains unlocked for 15 minutes.
Whenever there is activity on the screen, the system remains in this mode. If
the end of this 15 minutes is reached, the unit returns to USER mode.
If you forget the EXPERT level password, contact the Focke Meler main offices
to find out how to proceed to recover it.
Summary of Contents for PS 20 NON STOP+
Page 1: ...GLUING SOLUTIONS MA 5195 ENG 010620 ADHESIVE MELTER PS20 NON STOP INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 68: ...FOCKE MELER GLUING SOLUTIONS 4 42 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 6 2 TECHNICAL CHARACTERISTICS Dimensions ...
Page 81: ...ELECTRICAL DRAWINGS 7 1 MA 5195 ENG PS20 NON STOP DRUM UNLOADER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWING 16 17 19 18 10 11 12 13 14 15 ...
Page 86: ...FOCKE MELER GLUING SOLUTIONS 8 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Page 88: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...