FOCKE MELER GLUING SOLUTIONS
5-4
MAINTENANCE
5 Once completely empty, clean the any remaining adhesive from around
the output hole and chute.
6 Replace the plug.
7 Raise the emptying chute and replace the side shroud cap.
Warning:
Use appropriate protective equipment for high temperatures.
Cleaning the bottom of tank
It is often necessary to clean the bottom tank to remove PUR impurities on the
walls.
To do so, follow these instructions:
1 Remove the front and rear covers.
2 Remove the screws holding the side cover. The tank and distributors
should be completely accessible.