FOCKE MELER GLUING SOLUTIONS
INSTALLATION
3-2
Electrical Consumption
In order to install a PS20 NS+ melter, we should take into consideration the to-
tal consumption of the installation, including the consumption of the installed
hoses and applicators.
Before connecting, make sure that the voltage that is being connected to the
melter is the correct one appearing on the equipment’s characteristics plate.
Connect the machine and check to see if it is well grounded.
Warning
: Risk of electrocution. Even when the equipment is turned off, volta-
ge remains in the intake terminals, which may be dangerous during internal
equipment manipulations.
NS+ drum melters include a lockable voltage disconnection switch, which iso-
lates the equipment from its power source. It is protected from power surges
and short circuits by means of magnetothermic switches and it is equipped
with personal protection from branching to mass by way of a differential cir-
cuit breaker.
Consumption figures, according to melter and output configuration, are inclu-
ded in the table in the section ‘Electrical power connection’.
Compressed air
As an option, a pneumatically activated by-pass valve or an air drying system
may be installed. If these are added to the system, a dry, unlubricated com-
pressed air network must be available, with a maximum pressure of 6 bar.
In the case of the air drier, this depends on the frequency of application, and
therefore consumption must be estimated for each case. Generally speaking,
we can give a maximum consumption value of 4.5 l/min for a pressure of 0.5
bar with a standard cycle setting (10 min standby / 10 s application).
C
G
E
A
B
F
D
Summary of Contents for PS 20 NON STOP+
Page 1: ...GLUING SOLUTIONS MA 5195 ENG 010620 ADHESIVE MELTER PS20 NON STOP INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 68: ...FOCKE MELER GLUING SOLUTIONS 4 42 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 6 2 TECHNICAL CHARACTERISTICS Dimensions ...
Page 81: ...ELECTRICAL DRAWINGS 7 1 MA 5195 ENG PS20 NON STOP DRUM UNLOADER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWING 16 17 19 18 10 11 12 13 14 15 ...
Page 86: ...FOCKE MELER GLUING SOLUTIONS 8 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Page 88: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...