FOCKE MELER GLUING SOLUTIONS
5-2
MAINTENANCE
To carry out external cleaning:
• Use cleaning products compatible with polyamide materials.
• Apply the cleaning product with a soft cloth.
• Do not use sharp tools or scrapers with sharp edges.
Removing and changing exterior panels:
1. Disconnect the melter equipment.
2. Disconnect the compressed air from the equipment intake.
3. Turn counterclockwise 1/4 turn the two screws holding the panel.
4. Tilt the panel and pull it up by means of two handles placed below
fixing screws.
5. To replace the panels, follow steps 1 through 3 in the reverse order.
Depressurizing the system
Melting equipment belonging to the PS20 NS+ include a safety valve (a by-pass
valve) that limits the maximum pressure within the system, especially during
continuous pumping periods with closed applicator applicators.
However, even with the motor turned off, residual pressure may exist in the
circuit. This must be kept in mind when performing any operation on the
hydraulic circuit.
Before disconnecting any hydraulic element or opening any distributor outlet,
it is necessary to perform the following steps:
1. Disconnect the equipment switch located on the front.
2. Operate the purge valve housed in each distributor to free any residual
pressure from the circuit.
3. Manually purge (or use the corresponding control command) all the
applicators that have been used.
Cleaning the tank
The hot-melt tank must be cleaned on occasion to maintain its fusion and
anti-adherence properties. The tank is covered on the inside with PTFE and
inclined enough to aid unloading the hot-melt and to avoid it from being
retained inside when consequential burning occurs.
Changing adhesive type
1. Use up as much of the adhesive as possible.
If it is necessary to unload the adhesive without having used it up as much as
possible, follow the instructions in the section ‘Emptying the tank’.
Summary of Contents for PS 20 NON STOP+
Page 1: ...GLUING SOLUTIONS MA 5195 ENG 010620 ADHESIVE MELTER PS20 NON STOP INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 68: ...FOCKE MELER GLUING SOLUTIONS 4 42 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 6 2 TECHNICAL CHARACTERISTICS Dimensions ...
Page 81: ...ELECTRICAL DRAWINGS 7 1 MA 5195 ENG PS20 NON STOP DRUM UNLOADER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWING 16 17 19 18 10 11 12 13 14 15 ...
Page 86: ...FOCKE MELER GLUING SOLUTIONS 8 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Page 88: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...