MA-5195-ENG
PS20 NON STOP+ DRUM UNLOADER MANUAL
MELTER OPERATION
4-23
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
Manual OFF
T: Tank
External OFF
D: Distributor
1.1: Hose 1
1.2: Applicator 1
2.1: Hose 2
2.2: Applicator 2
3.1: Hose 3
3.2: Applicator 3
4.1: Hose 4
4.2: Applicator 4
5.1: Hose 5
5.2: Applicator 5
6.1: Hose 6
6.2: Applicator 6
Signal 1
Group 1: Robot Arm RIGHT
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
-20 °C
5 min
-10 °C
5 min
1.2 Sequential
Enable sequential
Define groups
Group B
Group C
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
Sequential group A
T: Tank
D: Distributor
1.1: Hose 1
1.2: Applicator 1
2.1: Hose 2
2.2: Applicator 2
3.1: Hose 3
3.2: Applicator 3
4.1: Hose 4
4.2: Applicator 4
5.1: Hose 5
5.2: Applicator 5
6.1: Hose 6
6.2: Applicator 6
1.3 Inhibitions
This menu allows you to create seven groups of zones and program the mode
in which the Inhibition (Off) can be activated or disabled.
The following is indicated for each group:
• Name of the group.
The name can be changed to identify it more easily.
• Manual inhibition of the group (Manual Off).
Whether it is possible to
manually activate or deactivate the inhibition in that group from the
‘SHORTCUTS’ menu.
Manual inhibition takes priority over external inhibition.
• Automatic inhibition with external signal (External Off).
Whether it is
possible to externally activate or deactivate the inhibition in that group.
You must indicate which of the seven possible external signals will
perform this function.
One signal can never be enabled in two different groups.
• Selected zones.
A zone may be selected in more than one group or may
not be in any grou.
1.2 Sequential Heating
This lets you start heating the zones one after the other. This prevents a zone
from being active for a long time until the slowest zone heats up.
This function allows you to create three heating groups: A, B and C. Press
‘Define groups’ to go to a screen where zones can be added to the groups:
• Group A:
this always includes the Tank, which is the slowest and serves
as a reference for the remainder of the zones. Other zones can be added
so they begin to heat up with the Tank.
• Group B:
other zones can be added and some degrees of temperature
defined before the tank reaches its set point and a wait time.
• Group C:
the zones that are not in group A or B can be added here.
If a component in group B or C is deselected, it goes back to group A. By
default, all the zones belong to group A.
Example:
- Tank set point temperature: 150°C
- Programming of Group B: -20°C / 5 minutes.
Group B begins to heat up 5 minutes after the tank reaches 130°C.
Summary of Contents for PS 20 NON STOP+
Page 1: ...GLUING SOLUTIONS MA 5195 ENG 010620 ADHESIVE MELTER PS20 NON STOP INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 68: ...FOCKE MELER GLUING SOLUTIONS 4 42 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 6 2 TECHNICAL CHARACTERISTICS Dimensions ...
Page 81: ...ELECTRICAL DRAWINGS 7 1 MA 5195 ENG PS20 NON STOP DRUM UNLOADER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWING 16 17 19 18 10 11 12 13 14 15 ...
Page 86: ...FOCKE MELER GLUING SOLUTIONS 8 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Page 88: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...