FOCKE MELER GLUING SOLUTIONS
5-8
MAINTENANCE
4. The amplifier that adjusts the sensor´s sensitivity is located in the control
cabinet.
This amplifier has two states indicated with two different LED colours (1):
• Green: no adhesive (empty).
• Yellow: there is adhesive (full).
5. Remove the plastic plug of the amplifier to access the sensitivity
adjustment potentiometer (2) and turn the adjusting screw at least 3 turns
counterclockwise. The LED must be green.
6. With the sensor still covered by melted adhesive, gently turn the adjusting
screw clockwise, just until the LED turns yellow (sensor activated).
7. Gently turn the adjusting screw ¼ turn counterclockwise. The LED will
change back to green.
1
1
2
2
Empty
Full
Verification of the sensor regulation
1. Increase slightly the adhesive level of the tank. The LED should change to
yellow.
2. Decrease the adhesive level of the tank. As soon as the detector is visible,
the LED should change to green.
It is recommended to carry out a verification of the signals once the equipment
is in automatic operation.
In NS+ melters, check which cylinder pushes the adhesive block when the
amplifier LED shows the green colour and stops pushing when it is yellow
colour
Summary of Contents for PS 20 NON STOP+
Page 1: ...GLUING SOLUTIONS MA 5195 ENG 010620 ADHESIVE MELTER PS20 NON STOP INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 68: ...FOCKE MELER GLUING SOLUTIONS 4 42 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 6 2 TECHNICAL CHARACTERISTICS Dimensions ...
Page 81: ...ELECTRICAL DRAWINGS 7 1 MA 5195 ENG PS20 NON STOP DRUM UNLOADER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWING 16 17 19 18 10 11 12 13 14 15 ...
Page 86: ...FOCKE MELER GLUING SOLUTIONS 8 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Page 88: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...