PS20 NON STOP+ DRUM UNLOADER MANUAL
MELTER OPERATION
4-25
(*) Example values
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
40 °C
200 °C
10 °C
60 s
20 °C
60 s
230 °C
10 s
10 min
60 s
10 °C
20 °C
1.5 Heating Extra Settings
Programmable limits
min
max
Temperature warning (+/-)
Temperature alarm in zone (+/-)
Total alarm due to temperature
Pumping permission delay
Adaptative time
1.5 Extra temperature settings
• Pumping permission delay:
This is the time that the unit must wait to
activate pumping after all the active zones have reached a temperature
above [Set point temp. -3°].
• Programmable limits:
Two limits can be set to prevent set point
temperatures from being programmed above or below those values.
• Temperature warning:
A temperate (±°C/°F) and a time are defined to
indicate when the overheating or low temperature warning is activated in
each zone.
• Temperature alarm:
A temperature (±°C/°F) and a time are defined to
indicate when the overheating or low temperature alarm is activated in
each zone.
If either of those values are reached (±) and maintained for the set time,
the unit disconnects the heating in the zone causing the error. If the error
persists 3 minutes later, the remainder of the zones are automatically
disconnected. If the affected zones are the tank or the distributor, the unit
also stops the pumping.
• Alarma total por temperatura:
Se define un valor (+°C/°F) y un
tiempo que indican cuando se activa la alarma por sobretemperatura.
Si cualquier zona alcanza esta temperatura y permanece el tiempo
establecido, el equipo desconecta el calentamiento de todas las zonas y
detiene el bombeo.
• Adaptive time:
Automatic interval setting for warning and alarm
temperatures, when the user reprogrammes the setpoint values.
Status
Actual
temperature*
Set point
emperature*
Heating
Pumping
OUTPUTS
Temp.OK
zones
Alarm
Activated
Ready /
Running
150
150
ON
ON
ON
OFF
ON / OFF
140
150
ON
ON
ON
ON
ON / OFF
160
130
150
OFF
Unit
OFF when...
Error in Tank
Error in Distributor
OFF
ON
ON/OFF
170
OFF
Zone in error
ON when...
Error in the remainder
of the Zones
190
150
OFF
All Zones
OFF
OFF
ON
OFF
Summary of Contents for PS 20 NON STOP+
Page 1: ...GLUING SOLUTIONS MA 5195 ENG 010620 ADHESIVE MELTER PS20 NON STOP INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 68: ...FOCKE MELER GLUING SOLUTIONS 4 42 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 6 2 TECHNICAL CHARACTERISTICS Dimensions ...
Page 81: ...ELECTRICAL DRAWINGS 7 1 MA 5195 ENG PS20 NON STOP DRUM UNLOADER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWING 16 17 19 18 10 11 12 13 14 15 ...
Page 86: ...FOCKE MELER GLUING SOLUTIONS 8 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Page 88: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...