PS20 NON STOP+ DRUM UNLOADER MANUAL
MELTER OPERATION
4-17
Modes of operation
Operating mode with internal pumping control and internal speed control
In this operating mode, the user manually controls the start-up, shutdown and
speed of the pump.
The ‘External reference’ and ‘External permission’ options must be
deactivated.
Follow the steps below to use this operating mode:
1. On the start screen, press the pump status icon to access the Pumping
Control menu.
2. On the Pumping Control menu, press the pump that you want to start
up. When the key is green, the pump is activated. When it is grey, the
pump is off.
The following conditions must be met for the pump to start operating:
•
The unit must be at ‘Temperature OK’.
•
The ‘Pumping permission delay’ time must have elapsed.
•
If ‘Pumping safety’ is activated, pumping must be enabled with the
‘STOP’ button (red LED off).
•
There must be no alarms preventing pumping.
If a speed has been previously set, this value will be shown on the
display and the pump will start to rotate at the speed indicated provided
that all prior conditions are met. Otherwise:
3. Press speed and set the new rotation speed. The pump will then start
rotating at the set RPM.
The maximum full scale for permissible RPM is 100 (we recommend
working at speeds no lower than 10 RPM and no greater than 80 RPM).
The minimum and maximum values that can be set are established
in the pump’s minimum and maximum speed alarms. See the point
‘Menu 5. Pumping/Pumping alarms’.
The pump will stop whenever:
• The control board is disabled using the ON/OFF button.
• The pumping ‘STOP’ button is pressed (red LED is lit).
• When a variator error signal is activated.
• When the MAXIMUM RPM alarm is activated.
• When the MINIMUM RPM alarm is activated.
4. If the unit has a rear switch connector (optional), pumping can also
be activated from the device associated with this connector. Both the
pumping button and switch must be connected to allow the pump to be
activated.
When the LED is green, the contact is closed and the pump can be
started up; when it is red, the contact is open and the pump will remain
off.
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
75 rpm
50 rpm
50 rpm
49 rpm
53 rpm
PUMP 1
Real speed:
External reference 1
External permission 1
Switch 1
Real speed:
External reference 2
External permission 2
Switch 2
PUMP 2
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
160
154
B
15:35
°C
08:31
2
00
154
1
85
1 2
B
A
VP
160
A
185
170
1
154
154
2
100
100
3
---
---
4
5
42
42
6
1
2
3
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
90 rmp
30 s
10 rpm
min
max
85 rmp
35 s
15 rpm
min
max
Pump 1 speed alarm
5. Pumping
Pump 2 speed alarm
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
75 rpm
50 rpm
50 rpm
49 rpm
53 rpm
PUMP 1
Real speed:
External reference 1
External permission 1
Switch 1
Real speed:
External reference 2
External permission 2
Switch 2
PUMP 2
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
75 rpm
50 rpm
50 rpm
49 rpm
53 rpm
PUMP 1
Real speed:
External reference 1
External permission 1
Switch 1
Real speed:
External reference 2
External permission 2
Switch 2
PUMP 2
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
75 rpm
50 rpm
50 rpm
49 rpm
53 rpm
PUMP 1
Real speed:
External reference 1
External permission 1
Switch 1
Real speed:
External reference 2
External permission 2
Switch 2
PUMP 2
4
4
4
Summary of Contents for PS 20 NON STOP+
Page 1: ...GLUING SOLUTIONS MA 5195 ENG 010620 ADHESIVE MELTER PS20 NON STOP INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 68: ...FOCKE MELER GLUING SOLUTIONS 4 42 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 6 2 TECHNICAL CHARACTERISTICS Dimensions ...
Page 81: ...ELECTRICAL DRAWINGS 7 1 MA 5195 ENG PS20 NON STOP DRUM UNLOADER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWING 16 17 19 18 10 11 12 13 14 15 ...
Page 86: ...FOCKE MELER GLUING SOLUTIONS 8 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Page 88: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...